MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2023.09.021

Медицинская библиотека · The American journal of cardiology · 2023

A Novel System for Transcatheter Aortic Valve Implantation: First-in-Man Study.

Liu Qingrong, Mei Ju, Zhang Hongliang, Zhou Wenbing, Qiu Kejin, Zhou Qing, Chen Yang, Duan Wei, Zhou Changping, Tang Min, Huang Jianbing, Liu Haixia, Liu Qingqing, Chang Rencao, Niu Guannan, Zhang Yuxin, Wu Tao, Zhang Ting, Fang Weiyi, Wu Yongjian, Gao Runlin

СтатьяПеревод пока не подготовлен

Аннотация

Transcatheter aortic valve implantation (TAVI) has become a therapeutic treatment for severe symptomatic patients with aortic stenosis. This study aimed to test a novel transcatheter aortic self-expandable bioprosthesis-the ScienCrown system (Lepu Medtech Inc., Beijing, China)-and evaluate the safety of the new device during TAVI. ScienCrown aortic valve implantation was performed on 10 patients. Clinical assessment was performed at baseline, post procedure, and after 1 year. Clinical outcomes and adverse events were assessed according to Valvular Academic Research Consortium-3 criteria. The mean age was 75.30 ± 4.78 years with a mean Society of Thoracic Surgeons score of 4.64 ± 3.23%. Device success was achieved in all patients (80% transfemoral, 20% transapical). After 1 year, there were no deaths, disabling strokes, myocardial infarctions, conversions to surgery, or major procedure-related complications. New pacemaker implantation was required in one patient (10%). ScienCrown implantation resulted in a reduction in mean valve gradient (63.00 ± 18.84 to 9.67 ± 4.97 mm Hg, p <0.001) and an increase in effective orifice area (0.57 ± 0.20 to 2.57 ± 0.59 cm2, p <0.001) at 1 year. Paravalvular leak was absent in 9 patients (90%), and there was a trace in one patient (10%). All patients were in New York Heart Association class I to II at a mean follow-up of 1 year. The experience showed that ScienCrown transcatheter aortic valve system was safely and successfully implanted for treatment of severe symptomatic aortic stenosis. The newer-generation device affords a stable implantation while providing optimal hemodynamic performance.

Для цитирования: Liu Qingrong, Mei Ju, Zhang Hongliang, Zhou Wenbing, Qiu Kejin, Zhou Qing, Chen Yang, Duan Wei, Zhou Changping, Tang Min, Huang Jianbing, Liu Haixia, Liu Qingqing, Chang Rencao, Niu Guannan, Zhang Yuxin, Wu Tao, Zhang Ting, Fang Weiyi, Wu Yongjian, Gao Runlin. A Novel System for Transcatheter Aortic Valve Implantation: First-in-Man Study.. The American journal of cardiology. 2023. DOI: 10.1016/j.amjcard.2023.09.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.