Carotid Duplex Ultrasonography to Assess Severity of Low-Flow Low-Gradient Aortic Stenosis.

Puthenpura Max, Alkhalfan Fahad, Ali Ambreen Fatima, Rajasekar Bhairavi, Akintoye Emmanuel, Fendrikova-Mahlay Natalia, Harb Serge, Cameron Scott J, Popović Zoran B, Chaudhury Pulkit

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with low-flow, low-gradient aortic valve stenosis constitute a substantial subset of all severe aortic stenosis patients. However, assessment of true severity of these patients can be challenging. In this analysis, we study the utility of the common carotid artery waveforms to distinguish true from pseudo-severe low-flow low-gradient aortic stenosis.

METHODS

This is an observational analysis that included patients who underwent a transthoracic echocardiogram (TTE) and duplex carotid ultrasonography (DCUS) and had low-flow, low-gradient aortic stenosis with reduced left ventricular ejection fraction (LVEF) on the index TTE (LVEF <50%, calculated aortic valve area [AVA] of ≤1.0 cm2, mean and peak gradient of <40 and <64 mm Hg, respectively, and stroke volume index <35 mL/m2). Patients were classified as pseudo-severe and true-severe aortic stenosis based on additional subsequent testing. Differences in various TTE and DCUS waveform parameters across the aortic valve and the common carotid artery were compared between the 2 groups.

RESULTS

The study included 30 patients (60 carotid arteries). Fifteen patients were categorized as pseudo-severe and 15 as true severe aortic stenosis. There were no significant differences in calculated AVA, LVEF, stroke volume/stroke volume index, and Doppler Velocity Index in the 2 groups. Mean and peak gradient were higher in patients with true-severe aortic stenosis. Carotid acceleration time (cAT) was significantly prolonged in patients with true-severe compared with pseudo-severe aortic stenosis. A cAT ≥80 ms was 83.3% sensitive and 83.3% specific for true-severe aortic stenosis.

CONCLUSION

cAT acceleration time may be used to distinguish true from pseudo-severe low-flow, low-gradient aortic valve stenosis.

Для цитирования: Puthenpura Max, Alkhalfan Fahad, Ali Ambreen Fatima, Rajasekar Bhairavi, Akintoye Emmanuel, Fendrikova-Mahlay Natalia, Harb Serge, Cameron Scott J, Popović Zoran B, Chaudhury Pulkit. Carotid Duplex Ultrasonography to Assess Severity of Low-Flow Low-Gradient Aortic Stenosis.. The American journal of medicine. 2023. DOI: 10.1016/j.amjmed.2023.12.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.