MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2023.12.007

Медицинская библиотека · The American journal of cardiology · 2023

Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A Nation-Wide Study.

Sa Young Kyoung, Choi Ik Jun, Chang Kiyuk, Hwang Byung-Hee, Chung Woo-Baek, Lee Kwan Yong, Choo Eun-Ho, Kim Chan Joon, Park Mahn Won, Choi Yoon Seok, Park Chul Soo, Yoo Ki Dong, Jeon Doo Soo, Oak Min-Ho, Lee Jungkuk, Kang Dongwoo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A few studies have reported comparative analysis of clinical outcomes between balloon-expandable valve (BEV) and self-expandable valve (SEV) after transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis using newer-generation devices. However, those reports were mostly limited to short-term outcomes and Western populations. In the present study, data of patients with severe aortic stenosis who underwent TAVR between March 2016 and December 2018 were obtained from the National Health Insurance Service in Korea. The primary end point, defined as all-cause mortality, was compared in BEV (SAPIEN 3, Edwards Lifesciences, Irvine, California) and SEV (Evolut R, Medtronic, Minneapolis, MN) groups using a propensity-score matching analysis. Cumulative event rates of ischemic stroke, repeat procedures, and permanent pacemaker insertion (PPI) were evaluated as secondary outcomes. All events were followed up to a maximum of 3 years. A total of 1,172 patients underwent transfemoral TAVR, of whom 707 (60.3%) were treated with BEV and 452 (38.6%) with SEV. After 1:1 propensity-score matching, the BEV group showed lower all-cause mortality after a median follow-up of 12.0 months (mean: 13.1 ± 9.3 months) based on Cox proportional hazard model analysis (hazard ratio [HR] 0.67, 95% confidence interval [CI] 0.45 to 0.99, p = 0.04). Cumulative incidence of ischemic stroke was not statistically different between the 2 groups (HR 0.68, 95% CI 0.29 to 1.59, p = 0.37). PPI occurred less frequently in the BEV group (HR 0.4, 95% CI 0.25 to 0.64, p < 0.01). Repeat procedures were rare (1 patient in BEV and 2 patients in SEV group). In conclusion, Korean nation-wide data analysis showed that BEV was associated with less all-cause death and incidence of PPI after TAVR than was SEV using a newer-generation device.

Для цитирования: Sa Young Kyoung, Choi Ik Jun, Chang Kiyuk, Hwang Byung-Hee, Chung Woo-Baek, Lee Kwan Yong, Choo Eun-Ho, Kim Chan Joon, Park Mahn Won, Choi Yoon Seok, Park Chul Soo, Yoo Ki Dong, Jeon Doo Soo, Oak Min-Ho, Lee Jungkuk, Kang Dongwoo. Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A Nation-Wide Study.. The American journal of cardiology. 2023. DOI: 10.1016/j.amjcard.2023.12.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.