MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/cncy.22898

Медицинская библиотека · Cancer cytopathology · 2024

Utilization of an artificial intelligence-enhanced, web-based application to review bile duct brushing cytologic specimens: A pilot study.

Marya Neil B, Powers Patrick D, Bois Melanie C, Hartley Christopher, Kerr Sarah E, Thangaiah Judith Jebastin, Norton Daniel, Abu Dayyeh Barham K, Cantley Richard, Chandrasekhara Vinay, Gores Gregory, Gleeson Ferga C, Law Ryan J, Maleki Zahra, Martin John A, Pantanowitz Liron, Petersen Bret, Storm Andrew C, Levy Michael J, Graham Rondell P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The authors previously developed an artificial intelligence (AI) to assist cytologists in the evaluation of digital whole-slide images (WSIs) generated from bile duct brushing specimens. The aim of this trial was to assess the efficiency and accuracy of cytologists using a novel application with this AI tool.

METHODS

Consecutive bile duct brushing WSIs from indeterminate strictures were obtained. A multidisciplinary panel reviewed all relevant information and provided a central interpretation for each WSI as being "positive," "negative," or "indeterminate." The WSIs were then uploaded to the AI application. The AI scored each WSI as positive or negative for malignancy (i.e., computer-aided diagnosis [CADx]). For each WSI, the AI prioritized cytologic tiles by the likelihood that malignant material was present in the tile. Via the AI, blinded cytologists reviewed all WSIs and provided interpretations (i.e., computer-aided detection [CADe]). The diagnostic accuracies of the WSI evaluation via CADx, CADe, and the original clinical cytologic interpretation (official cytologic interpretation [OCI]) were compared.

RESULTS

Of the 84 WSIs, 15 were positive, 42 were negative, and 27 were indeterminate after central review. The WSIs generated on average 141,950 tiles each. Cytologists using the AI evaluated 10.5 tiles per WSI before making an interpretation. Additionally, cytologists required an average of 84.1 s of total WSI evaluation. WSI interpretation accuracies for CADx (0.754; 95% CI, 0.622-0.859), CADe (0.807; 95% CI, 0.750-0.856), and OCI (0.807; 95% CI, 0.671-0.900) were similar.

CONCLUSIONS

This trial demonstrates that an AI application allows cytologists to perform a triaged review of WSIs while maintaining accuracy.

Для цитирования: Marya Neil B, Powers Patrick D, Bois Melanie C, Hartley Christopher, Kerr Sarah E, Thangaiah Judith Jebastin, Norton Daniel, Abu Dayyeh Barham K, Cantley Richard, Chandrasekhara Vinay, Gores Gregory, Gleeson Ferga C, Law Ryan J, Maleki Zahra, Martin John A, Pantanowitz Liron, Petersen Bret, Storm Andrew C, Levy Michael J, Graham Rondell P. Utilization of an artificial intelligence-enhanced, web-based application to review bile duct brushing cytologic specimens: A pilot study.. Cancer cytopathology. 2024. DOI: 10.1002/cncy.22898.