The Clinical journal of pain · 2008
Effect of microneedle design on pain in human volunteers.
Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gill Harvinder S, Denson Donald D, Burris Brett A, Prausnitz Mark R
Аннотация
OBJECTIVES: To design microneedles that minimize pain, this study tested the hypothesis that microneedles cause significantly less pain than a 26-gauge hypodermic needle, and that decreasing microneedle length and the number of microneedles reduces pain in normal human volunteers.
METHODS: Single microneedles with lengths ranging from 480 to 1450 microm, widths from 160 to 465 microm, thicknesses from 30 to 100 microm, and tip angles from 20 to 90 degrees; and arrays containing 5 or 50 microneedles were inserted into the volar forearms of 10 healthy, human volunteers in a double-blinded, randomized study. Visual analog scale pain scores were recorded and compared with each other and to the pain from a 26-gauge hypodermic needle.
RESULTS: All microneedles investigated were significantly less painful than the hypodermic needle with microneedle pain scores varying from 5% to 40% of the hypodermic needle. Microneedle length had the strongest effect on pain, where a 3-fold increase in length increased the pain score by 7-fold. The number of microneedles also affected the pain score, where a 10-fold increase in the number of microneedles increased pain just over 2-fold. Microneedle tip angle, thickness, and width did not significantly influence pain.
DISCUSSION: Microneedles are significantly less painful than a 26-gauge hypodermic needle over the range of dimensions investigated. Decreasing microneedle length and number of microneedles reduces pain.
METHODS: Single microneedles with lengths ranging from 480 to 1450 microm, widths from 160 to 465 microm, thicknesses from 30 to 100 microm, and tip angles from 20 to 90 degrees; and arrays containing 5 or 50 microneedles were inserted into the volar forearms of 10 healthy, human volunteers in a double-blinded, randomized study. Visual analog scale pain scores were recorded and compared with each other and to the pain from a 26-gauge hypodermic needle.
RESULTS: All microneedles investigated were significantly less painful than the hypodermic needle with microneedle pain scores varying from 5% to 40% of the hypodermic needle. Microneedle length had the strongest effect on pain, where a 3-fold increase in length increased the pain score by 7-fold. The number of microneedles also affected the pain score, where a 10-fold increase in the number of microneedles increased pain just over 2-fold. Microneedle tip angle, thickness, and width did not significantly influence pain.
DISCUSSION: Microneedles are significantly less painful than a 26-gauge hypodermic needle over the range of dimensions investigated. Decreasing microneedle length and number of microneedles reduces pain.