DOI 10.1016/j.ejso.2022.07.004
Axillary reverse mapping using near-infrared fluorescence imaging in invasive breast cancer (ARMONIC study).
Аннотация
BACKGROUND
Axillary lymph node dissection (ALND) in patients with breast cancer has potential side effects, including upper-limb lymphedema. Axillary reverse mapping (ARM) is a technique that enables discrimination of the lymphatic drainage of the upper limb in the axillary lymph node basin from that of the breast. We aimed to evaluate ARM node identification by near-infrared (NIR) fluorescence imaging during total mastectomy with ALND and then to analyze potential predictive factors of ARM node involvement.
METHODS
The study enrolled 119 patients diagnosed with invasive breast cancer with an indication for ALND. NIR imaging using indocyanine green dye was performed in 109 patients during standard ALND to identify ARM nodes and their corresponding lymphatic ducts.
RESULTS
94.5% of patients had ARM nodes identified (95%CI = [88.4-98.0]). The ARM nodes were localized in zone D in 63.4% of cases. Metastatic axillary lymph nodes were found in 55% in the whole cohort, and 19.4% also had metastasis in ARM nodes. Two patients had metastatic ARM nodes but not in the remaining axillary lymph nodes. No serious adverse events were observed. Only the amount of mitosis was significantly associated with ARM node metastasis.
CONCLUSIONS
ARM by NIR fluorescence imaging could be a reliable technique to identify ARM nodes in real-time when ALND is performed. The clinical data compared with ARM node histological diagnosis showed only the amount of mitosis in the diagnostic biopsy is a potential predictive factor of ARM node involvement.
CLINICAL TRIAL REGISTRATION: NCT02994225.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.