MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10549-022-06556-w

Медицинская библиотека · Breast cancer research and treatment · 2022

Validation sentinel lymph node biopsy study in cN0 axilla using low-cost dual dye technique: potential solution for resource poor settings.

Chavda Jayesh, Mishra Arpan, Silodia Ashutosh, Yadav Sanjay Kumar, Sharma Deepti Bala, Sharma Dhananjaya, Khandare Muktesh

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Sentinel lymph node biopsy (SLNB) using radio-pharmaceutical and a blue dye is gold standard for axillary staging in clinically node-negative breast cancer. High costs and limited availability of radio-pharmaceutical and/or gamma probe are major deterrents in performing SLNB in developing countries. In this study, we evaluated feasibility of SLN identification (SLN-IR) of fluorescein-guided (FG) SLNB in combination with methylene blue dye (MBD).

METHODS

This was a prospective cross-sectional non-randomized validation study in patients with clinically node-negative axilla. Patients underwent validation SLNB using fluorescein (and blue LED light) and MBD. Axillary dissection was performed irrespective of SLNB histology. SLIN-IR and False Negative Rate (FNR) were assessed for both groups.

RESULTS

The SLNs were identified in 29 (96.6%) pre-chemotherapy patients and 23 (82%) post Neoadjuvant Chemotherapy (NACT) patients. The median number of sentinel lymph nodes identified was 3 (range of 1-5) in pre-chemotherapy patients and 1 (range of 1-3) in post NACT patients. The SLN-IR using MBD was 90%, FD was 86.7% and combined MBD FD was 96.7% in pre-chemotherapy patients. The SLN-IR using MBD was 82%, FD was 71% and combined MBD FD was 82% in in post NACT patients. The false negative rate (FNR) in pre-chemotherapy group was 8.0% (MBD), 8.3% (FD) and 7.4% (MBD + FD). The FNR in post NACT group was 8.7% (MBD), 10% (FD) and 8.7% (MBD + FD).

CONCLUSION

This prospective validation study showed adequate SLN-IR and FNR using low-cost dual dyes in early breast cancer patients and can be used in low resource settings. However, SLNB in post NACT axilla though viable along with a satisfactory FNR, is associated with low identification rate and needs further evaluation.

Для цитирования: Chavda Jayesh, Mishra Arpan, Silodia Ashutosh, Yadav Sanjay Kumar, Sharma Deepti Bala, Sharma Dhananjaya, Khandare Muktesh. Validation sentinel lymph node biopsy study in cN0 axilla using low-cost dual dye technique: potential solution for resource poor settings.. Breast cancer research and treatment. 2022. DOI: 10.1007/s10549-022-06556-w.