INTRODUCTION

Few studies have demonstrated a high degree of atrioventricular (AV) synchrony with a new leadless pacemaker called Micra AV. Our group previously reported a new and unique sensing method. We believe that this novel sensing method, "Simplified A3 method," might facilitate better AV synchrony than a conventional sensing method in almost all cases with Micra AV implantation.

METHODS

We conducted a non-randomized retrospective study comparing the two pacing methods at two centers. From December 1, 2021 to October 31, 2022, Micra AV was implanted for 32 patients at the two centers. Twenty of the 32 patients with sinus rhythm and complete AV block were included in this study. In Group 1, the conventional setting was programmed as follows: auto A3 threshold, auto A3 window-end (WE), and auto A4 threshold turned on during hospitalization. In Group 2, the "Simplified A3 method" was programmed as follows: auto A3 threshold and auto A3WE turned off. Instead, an intentionally prolonged A3WE (850-1000 ms) and low A3 threshold (A3 signal amplitude + 0.5-1.0 m/s2) were programmed.

RESULTS

Twenty patients were analyzed. In Group 2, AV synchrony (%AMVp) was significantly higher at the first outpatient clinic (63.0 ± 5.7% vs 81.0 ± 4.2%, p = .03). A3 threshold was significantly lower in Group 2 (5.9 ± 0.7 m/s2, p < .05 vs 2.3 ± 0.5 m/s2, p < .05).

CONCLUSION

Our novel sensing method might be a more feasible sensing method for obtaining higher AV synchrony than the conventional algorithm.

Для цитирования: Kazawa Shuichiro, Kazawa Chifumi, Sakaida Tomoko, Murakami Hidetaka, Takada Yasuyuki, Kusume Takahiro, Terasawa Muryo, Tanaka Nobuhiro, Satomi Kazuhiro, Yazaki Yoshinao. Feasibility of a novel atrial mechanical sensing method for leadless atrioventricular synchronous pacing.. Journal of cardiovascular electrophysiology. 2024. DOI: 10.1111/jce.16255.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.