MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2015.09.027

Медицинская библиотека · JACC. Cardiovascular interventions · 2016

Prospective Multicenter Evaluation of the Direct Flow Medical Transcatheter Aortic Valve System: 12-Month Outcomes of the Evaluation of the Direct Flow Medical Percutaneous Aortic Valve 18F System for the Treatment of Patients With Severe Aortic Stenosis (DISCOVER) Study.

Lefèvre Thierry, Colombo Antonio, Tchétché Didier, Latib Azeem, Klugmann Silvio, Fajadet Jean, De Marco Federico, Maisano Francesco, Bruschi Giuseppe, Bijuklic Klaudija, Nava Stefano, Weissman Neil, Low Reginald, Thomas Martyn, Young Christopher, Redwood Simon, Mullen Michael, Yap John, Grube Eberhard, Nickenig Georg, Sinning Jan-Malte, Hauptmann Karl Eugen, Friedrich Ivar, Lauterbach Michael, Schmoeckel Michael, Davidson Charles, Schofer Joachim

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to assess the 1-year outcome after transcatheter aortic valve replacement (TAVR) of the Direct Flow Medical (DFM) valve in patients with severe symptomatic aortic stenosis who were contraindicated or high risk for surgery.

BACKGROUND

The DFM transcatheter heart valve is a new-generation, nonmetallic aortic valve with a pressurized support structure and conformable double-ring annular sealing delivered through an 18-F sheath. The device allows repositioning, retrieval, and assessment of valve performance before permanent implantation.

METHODS

A prospective multicenter European registry was set up to determine the safety and performance of the valve in 100 consecutive patients (10 centers). Echocardiographic and angiographic data were evaluated by an independent core laboratory, and adverse events were adjudicated by a clinical events committee using Valve Academic Research Consortium criteria.

RESULTS

Patients were 83.1 ± 5.9 years of age and had a logistic EuroSCORE of 22.5 ± 11.3% and a Society of Thoracic Surgeons score of 9.7 ± 8.7%. Correct valve positioning was obtained in 99% of cases with a combined 30-day safety endpoint at 10%, including major stroke in 5.0%, major vascular complications in 2.0%, and death in 1%. At 12 months, 95% of patients were in New York Heart Association functional class I or II. Freedom from any death was 90%, and freedom from any death or major stroke was 85%. Echocardiography demonstrated none/trace to mild aortic regurgitation in 100% of patients and an unchanged mean aortic gradient of 12.2 ± 6.6 mm Hg and effective orifice area of 1.6 ± 0.4 cm(2).

CONCLUSIONS

At 1 year, the DFM transcatheter heart valve had durable hemodynamics. This study demonstrates that the low rate of early complications and the low risk of significant aortic regurgitation translated into midterm clinical benefit.

Для цитирования: Lefèvre Thierry, Colombo Antonio, Tchétché Didier, Latib Azeem, Klugmann Silvio, Fajadet Jean, De Marco Federico, Maisano Francesco, Bruschi Giuseppe, Bijuklic Klaudija, Nava Stefano, Weissman Neil, Low Reginald, Thomas Martyn, Young Christopher, Redwood Simon, Mullen Michael, Yap John, Grube Eberhard, Nickenig Georg, Sinning Jan-Malte, Hauptmann Karl Eugen, Friedrich Ivar, Lauterbach Michael, Schmoeckel Michael, Davidson Charles, Schofer Joachim. Prospective Multicenter Evaluation of the Direct Flow Medical Transcatheter Aortic Valve System: 12-Month Outcomes of the Evaluation of the Direct Flow Medical Percutaneous Aortic Valve 18F System for the Treatment of Patients With Severe Aortic Stenosis (DISCOVER) Study.. JACC. Cardiovascular interventions. 2016. DOI: 10.1016/j.jcin.2015.09.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.