MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2015.12.004

Медицинская библиотека · Journal of cardiovascular computed tomography · 2015

3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.

Ripley Beth, Kelil Tatiana, Cheezum Michael K, Goncalves Alexandra, Di Carli Marcelo F, Rybicki Frank J, Steigner Mike, Mitsouras Dimitrios, Blankstein Ron

Клиническое исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions.

OBJECTIVE

To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR).

METHODS

This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test.

RESULTS

Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of -0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive).

CONCLUSIONS

Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR.

Для цитирования: Ripley Beth, Kelil Tatiana, Cheezum Michael K, Goncalves Alexandra, Di Carli Marcelo F, Rybicki Frank J, Steigner Mike, Mitsouras Dimitrios, Blankstein Ron. 3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.. Journal of cardiovascular computed tomography. 2015. DOI: 10.1016/j.jcct.2015.12.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.