m+Medelevator.RU
← Поиск публикаций
Clinical research in cardiology : official journal of the German Cardiac Society · 2015

Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schaefer Andreas, Linder Matthias, Treede Hendrik, Deuschl Florian, Schofer Niklas, Seiffert Moritz, Schneeberger Yvonne, Blankenberg Stefan, Reichenspurner Hermann, Schaefer Ulrich, Conradi Lenard

Аннотация

OBJECTIVES: Physicians are frequently confronted with patients suffering from aortic stenosis with annular diameters exceeding dimensions in which currently available transcatheter heart valves (THV) are formally approved. Experience in patients receiving significantly undersized Sapien 3 (S3) THV (Edwards Lifesciences, Inc., Irvine, CA, USA) in aortic annuli up to 32 mm has not been reported so far.

METHODS: Patients with aortic annuli exceeding the formally determined upper size limit and who received a 29 mm S3, were identified from our database. Calcification pattern and annulus dimension were analyzed retrospectively using the 3mensio Medical Imaging software. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-2 definitions.

RESULTS: 21 consecutive patients with aortic annuli ≥28.1 mm received a 29 mm THV. All patients were male (77.4 ± 8.1 year, logEuroSCORE I 22.5 ± 14.1 %). Multi-slice computed tomography and transesophageal echocardiography derived annular dimensions were 30.2 ± 1.5 vs. 28.8 ± 0.9 mm (p = 0.0001). Total calcium load of the aortic valves was 1327 ± 957 mm(3). Device success according to VARC-2 definitions was achieved in 100 % (21/21). All-cause 30-day mortality was 0 % (0/21). Rate of permanent pacemaker implantation was 14.3 % (3/21). No paravalvular leakage ≥ grade II was detectable.

CONCLUSIONS: Preliminary experience suggests implantation of this type of THV in aortic annuli up to 32 mm to be feasible and safe, in particular calcification patterns. It does not result in a relevant incidence of PVL ≥ grade II, or increased rate of VARC-2 adjudicated clinical endpoints. Also, functional outcomes regarding transvalvular gradients or EOA demonstrate applicability of this THV in such patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты