DOI 10.4244/eijy15m10_08

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2016

Four-year durability of clinical and haemodynamic outcomes of transcatheter aortic valve implantation with the self-expanding CoreValve.

Gulino Simona, Barbanti Marco, Deste Wanda, Immè Sebastiano, Aruta Patrizia, Bottari Vera, Benvenuto Emanuele, Tamburino Claudia, Di Landro Alessio, Liberto Daria, Santonoceto Letizia, Sicuso Rita, Di Stefano Daniele, Todaro Denise, Di Simone Emanuela, Indelicato Antonino, Giannazzo Daniela, Sgroi Carmelo, Tamburino Corrado

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Long-term data on the durability of currently available transcatheter heart valves are limited. We sought to assess four-year clinical and echocardiographic outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) with the CoreValve prosthesis.

METHODS AND

RESULTS

Between June 2007 and February 2014, 450 consecutive patients with symptomatic severe aortic stenosis underwent TAVI in our institution. For the purposes of this study, we included only those patients undergoing successful TAVI with the CoreValve prosthesis who had a minimum follow-up of four years (n=125). Survival rates at one, two, three and four years were 83.2, 76.8, 73.6 and 66.3%, respectively. Aortic regurgitation was a common finding after the procedure, especially due to paravalvular regurgitation (PVR), which was observed in the majority of patients (71.5%), mostly mild (52.0%). Progression from mild acute PVR to moderate PVR at four-year follow-up was reported in three patients. No cases of severe PVR were observed. Prosthetic valve failure was reported in four patients (3.2%).

CONCLUSIONS

Our study demonstrates that favourable outcomes after successful TAVI are associated with sustained clinical and functional cardiovascular benefits up to four-year follow-up. Signs of moderate prosthetic valve failure are present only in a small percentage of patients.

Для цитирования: Gulino Simona, Barbanti Marco, Deste Wanda, Immè Sebastiano, Aruta Patrizia, Bottari Vera, Benvenuto Emanuele, Tamburino Claudia, Di Landro Alessio, Liberto Daria, Santonoceto Letizia, Sicuso Rita, Di Stefano Daniele, Todaro Denise, Di Simone Emanuela, Indelicato Antonino, Giannazzo Daniela, Sgroi Carmelo, Tamburino Corrado. Four-year durability of clinical and haemodynamic outcomes of transcatheter aortic valve implantation with the self-expanding CoreValve.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2016. DOI: 10.4244/eijy15m10_08.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.