First experience with the new Sorin Crown PRT bioprosthetic aortic valve: early postoperative outcome and hemodynamic performance in 90 patients.

Pollari F, Dinges C, Vogt F, Sirch J, Pfeiffer S, Seitelberger R, Fischlein T, Santarpino G

Clinical StudyСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

AIM: The Crown PRT (The Phospholipid Reduction Treatment) is a new stent bovine bioprosthesis for aortic valve replacement (AVR). Aim of this paper is to report the postoperative clinical and hemodynamic results after ninety consecutive implants.

METHODS

After receiving CE mark in July 2014, two European university centers implanted the new Crown PRT (Sorin Group, Burnaby, Canada) for the first time. Up to now, ninety patients underwent aortic valve replacement, in isolated or combined procedures, for aortic stenosis or insufficiency. Intraoperative transesophageal echocardiogram was used to assess the prosthesis's function. In hospital outcomes and echocardiographic parameters were recorded.

RESULTS

Age and Log Euroscore were 71.8±7.9 years and 10.2%±4.5 respectively. In-hospital mortality for isolated AVR was 0%; one patient died after a multiple procedure (overall 30-days mortality 1.1%). No adverse device effects were recorded. Intensive Care Unit stay was 2±5.8 days. At discharge, echocardiogram showed no paravalvular leaks and normal postoperative gradients.

CONCLUSION

Our starting results showed that the Crown PRT is safe and reliable, with excellent hemodynamic performance. Further clinical results with a larger population and long term follow-up are needed to assess the versatility and the durability of this new device.

Для цитирования: Pollari F, Dinges C, Vogt F, Sirch J, Pfeiffer S, Seitelberger R, Fischlein T, Santarpino G. First experience with the new Sorin Crown PRT bioprosthetic aortic valve: early postoperative outcome and hemodynamic performance in 90 patients.. The Journal of cardiovascular surgery. 2015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.