MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2015.06.045

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2015

Right anterior minithoracotomy for aortic valve replacement: 10-year experience of a single center.

Glauber Mattia, Gilmanov Daniyar, Farneti Pier Andrea, Kallushi Enkel, Miceli Antonio, Chiaramonti Francesca, Murzi Michele, Solinas Marco

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Minimally invasive aortic valve replacement (AVR) has been associated with several better outcomes over the standard full sternotomy approach. We revised our 10-year experience with right anterior minithoracotomy (RAMT) for AVR.

METHODS

Between 2004 and 2014, a total of 593 patients (310 men; median age: 73.8 years) underwent AVR via RAMT. Preoperatively, a mixed valve lesion was diagnosed in 55 (9.3%) patients; and pure aortic regurgitation in 86 (14.5%). Mean logistic EuroSCORE I (European system for cardiac operative risk evaluation) was 7.4 (median: 5.76).

RESULTS

In 302 (50.9%) patients, a sutureless or rapidly implantable biological prosthesis was used; in 23 (3.9%), a mechanical prosthesis; and in the remainder, a conventional biological prosthesis. A total of 113 (19.1%) patients had a small aortic annulus (≤21 mm). Operative times averaged 80 (median: 74) minutes of crossclamping time, and 117 (107) minutes of perfusion time; these were significantly shorter with a sutureless prostheses, compared with a sutured prostheses: perfusion 99 versus 134 minutes, P < .0005; aortic crossclamping time: 64 versus 97 minutes, P < .0005. The mean (median) assisted ventilation time was 9.8 (6) hours; intensive care unit stay was 1.5 (1) days; hospital length of stay was 6.6 (6) days. Overall in-hospital mortality was 9 deaths (1.5%). At 31.5 months mean follow-up time (1531 cumulative patient-years), 94.8% survival was observed.

CONCLUSIONS

Minimally invasive AVR is a safe procedure, with low perioperative morbidity, and low rates of reoperation and death at late follow-up. Excellent outcomes can be achieved with minimally invasive AVR via right anterior minithoracotomy. Sutureless prostheses facilitate minimally invasive AVR and are associated with reduced operative times.

Для цитирования: Glauber Mattia, Gilmanov Daniyar, Farneti Pier Andrea, Kallushi Enkel, Miceli Antonio, Chiaramonti Francesca, Murzi Michele, Solinas Marco. Right anterior minithoracotomy for aortic valve replacement: 10-year experience of a single center.. The Journal of thoracic and cardiovascular surgery. 2015. DOI: 10.1016/j.jtcvs.2015.06.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.