DOI 10.1097/00000658-200002000-00012
Preoperative evaluation of patients with primary head and neck cancer using dual-head 18fluorodeoxyglucose positron emission tomography.
Аннотация
OBJECTIVE
To evaluate the value of 18fluorodeoxyglucose (FDG) positron emission tomography (PET) in primary head and neck cancer.
BACKGROUND DATA: Head and neck carcinomas tend to metastasize to regional lymph nodes rather than to spread hematogenously. With nodal metastases, cure rates decrease by approximately 50%. Moreover, in approximately 3% of the patients, a second primary tumor is found at initial presentation.
METHODS
Fifty-four consecutive patients (31 men and 23 women; mean age 60 years, range 34-81 years) with previously untreated squamous cell carcinomas of the oral cavity or oropharynx were studied. Before surgery and within a period of 3 weeks, clinical examination, chest x-ray, computed tomography (CT), ultrasonography with fine-needle aspiration cytology (US/ FNAC), and FDG-PET were performed. All study results were scored per neck side and were also classified as 0 (no metastases), 1 (single metastasis), or 2 (multiple metastases).
RESULTS
The sensitivity for the detection of lymph node metastases per neck side was 96%, 85%, and 64% for FDG-PET, CT, and US/FNAC, respectively. The specificity was 90%, 86%, and 100% for FDG-PET, CT, and US/FNAC, respectively. In terms of the classification, FDG-PET showed the best correlation with the histologic data. Finally, in nine patients (17%), a second primary tumor was detected by FDG-PET and confirmed by histologic evaluation.
CONCLUSION
Because of the high prevalence of second primary tumors detected by FDG-PET and the decreased error rate in the assessment of lymph node involvement compared with CT and US, FDG-PET should be routinely performed in patients with primary head and neck cancer.