MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0067417

Медицинская библиотека · PloS one · 2013

Comparison of 24-h urinary aldosterone level and random urinary aldosterone-to-creatinine ratio in the diagnosis of primary aldosteronism.

Wu Che-Hsiung, Yang Ya-Wen, Hu Ya-Hui, Tsai Yao-Chou, Kuo Ko-Lin, Lin Yen-Hung, Hung Szu-Chun, Wu Vin-Cent, Wu Kwan-Dun, Taiwan Primary Aldosteronism Investigation (TAIPAI) Study Group

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Historically, urinary aldosterone level measurement was a commonly employed confirmatory test to detect primary aldosteronism (PA). However, 24-h urine collection is inconvenient and cumbersome. We hypothesized that random urinary aldosterone measurements with correction for creatinine concentration might be comparable to 24-h urinary aldosterone levels (Uald-24 h) in the diagnosis of PA.

METHODS

The non-concurrent prospective study was conducted between June 2006 and March 2008 in patients admitted for confirmation of aldosteronism by salt loading test. A 24-h urine sample, which was collected during hospitalization on the day before saline infusion testing after restoration of serum hypokalemia, was collected from all subjects. Moreover, participants were asked to collect a first bladder voiding random urine sample during clinic visits. Uald-24 h and the random urinary aldosterone-to-creatinine ratio (UACR) were calculated accordingly.

RESULTS

A total of 102 PA patients (71 patients diagnosed of aldosterone-producing adenoma, 31 with idiopathic hyperaldosteronism) and 65 patients with EH were enrolled. The receiver operating characteristic curve showed comparable areas under the curves of UACR and Uald-24 h. The Bland-Altman plot showed mean bias but no obvious heteroscedasticity between the two tests. When using random UACR >3.0 ng/mg creatinine as the cutoff value, we obtained a specificity of 90.6% to confirm PA from essential hypertension.

CONCLUSIONS

Our study reinforce that the diagnostic accuracy of random UACR was comparable to that of Uald-24 h in PA patients. With the quickness and simplicity of the UACR method and its equivalence to Uald-24 h, this assay could be a good alternative diagnostic tool for PA confirmation.

Для цитирования: Wu Che-Hsiung, Yang Ya-Wen, Hu Ya-Hui, Tsai Yao-Chou, Kuo Ko-Lin, Lin Yen-Hung, Hung Szu-Chun, Wu Vin-Cent, Wu Kwan-Dun, Taiwan Primary Aldosteronism Investigation (TAIPAI) Study Group. Comparison of 24-h urinary aldosterone level and random urinary aldosterone-to-creatinine ratio in the diagnosis of primary aldosteronism.. PloS one. 2013. DOI: 10.1371/journal.pone.0067417.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.