BACKGROUND

Computed Tomography (CT) imaging is essential for disease detection but carries a risk of cancer due to X-ray exposure. Typically, assessing this risk requires segmentation of the internal organ contours to predict organ doses, which hinders its clinical application. This study introduces a method that uses support vector regression (SVR) models trained on skin outline radiomic features to predict organ doses without organ segmentation, thus streamlining the process for clinical use.

METHODS

CT scans of the head and abdomen were used to extract radiomic features of the skin outline. These features were used as inputs, with organ doses from Monte Carlo simulations as benchmarks to train the SVR models for predicting organ doses. The accuracy of the models was evaluated using the mean absolute percentage error (MAPE) and coefficient of determination (R2).

RESULTS

The results showed a high precision in dose prediction for various organs, including the brain (MAPE: 1.5%, R2: 0.9), eyes (MAPE: 5%, R2: 0.84), lens (MAPE: 5%, R2: 0.82), bowel (MAPE: 6%, R2: 0.84), kidneys (MAPE: 7.5%, R2: 0.7), and liver (MAPE: 8%, R2: 0.67). Internal organ disturbances had a minimal impact on accuracy.

CONCLUSIONS

The SVR models efficiently predicted patient-specific organ doses from CT scans, offering a user-friendly tool for rapid segmentation-free dose prediction. This innovation can significantly enhance clinical efficiency and accessibility in predicting patient-specific organ doses using CT.

Для цитирования: Shao Wencheng, Qu Liangyong, Lin Xin, Huang Ying, Zhuo Weihai, Liu Haikuan. Fast estimation of patient-specific organ doses from abdomen and head CT examinations without segmenting internal organs using machine learning models.. Precision radiation oncology. 2025. DOI: 10.1002/pro6.70016.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.