Медицинская библиотека · American journal of clinical oncology · 2014

Cost-effectiveness of 3-dimensional conformal radiotherapy and applicator-based brachytherapy in the delivery of accelerated partial breast irradiation.

Shah Chirag, Lanni Thomas, Wilkinson John Ben, Jawad Maha, Wobb Jessica, Berry Sameer, Wallace Michelle, Chen Peter, Grills Inga S

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare reimbursement and cost efficacy between accelerated partial breast irradiation (APBI) techniques.

MATERIALS/

METHODS

Four hundred fifty-three patients were treated with APBI using either 3-dimensional conformal radiotherapy (3D-CRT, n=207) or balloon-based brachytherapy (BB) [single-lumen (SL, n=161) and multilumen (ML, n=85)] between March 2000 and October 2011. To evaluate cost-effectiveness, reimbursement by treatment technique was calculated based on 2011 Medicare schedules. Facility costs were generated by technique based on ICD-9 codes. Incremental cost effectiveness ratios (ICER), which compares cost with clinical outcomes, were calculated according to the difference in reimbursement to the criteria being evaluated.

RESULTS

With a median follow-up of 3.6 years, the 5-year rate of local recurrence was 1.9% for all patients (3D-CRT, 0%; BB, 4.1%; P=0.23). When pooled, BB patients had a significant improvement in excellent/good cosmesis (91.6% vs. 80.0%; P=0.03). Rates of combined grade 2 or higher dermatitis, hyper/hypopigmentation, pain, or fibrosis per technique were 62%, 28%, and 34% for 3D-CRT, SL, and ML patients, respectively (P=0.26). The ICER per percent improved cosmesis for SL/ML was $519/$850 based on reimbursement and $301/$643 based on cost compared with 3D-CRT.

CONCLUSIONS

On the basis of ICER, brachytherapy for APBI is a cost-effective option with regard to cosmesis and toxicity. This economic analysis suggests the increased cost of applicator-based brachytherapy may be justified in appropriately selected patients.

Для цитирования: Shah Chirag, Lanni Thomas, Wilkinson John Ben, Jawad Maha, Wobb Jessica, Berry Sameer, Wallace Michelle, Chen Peter, Grills Inga S. Cost-effectiveness of 3-dimensional conformal radiotherapy and applicator-based brachytherapy in the delivery of accelerated partial breast irradiation.. American journal of clinical oncology. 2014. DOI: 10.1097/coc.0b013e318271b16d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.