MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2021.01.022

Медицинская библиотека · The American journal of cardiology · 2021

Long-term Implications of Post-Procedural Left Ventricular End-Diastolic Pressure in Patients Undergoing Transcatheter Aortic Valve Implantation.

Szekely Yishay, Borohovitz Ariel, Hochstadt Aviram, Topilsky Yan, Konigstein Maayan, Halkin Amir, Bazan Samuel, Banai Shmuel, Finkelstein Ariel, Arbel Yaron

СтатьяПеревод пока не подготовлен

Аннотация

Current risk models have only limited accuracy in predicting transcatheter aortic valve Implantation (TAVI) outcomes and there is a paucity of clinical variables to guide patient management after the procedure. The prognostic impact of elevated left ventricular end-diastolic pressure (LVEDP) in TAVI patients is unknown. The aim of the present study was to evaluate the prognostic value of after-procedural LVEDP in patients who undewent TAVI. Consecutive patients with severe symptomatic aortic stenosis who undewent TAVI were divided into 2 groups according to after-procedural LVEDP above and below or equal 12 mm Hg. Collected data included baseline clinical, laboratory and echocardiographic variables. We evaluated the impact of elevated vs. normal LVEDP on in-hospital outcomes, short- and long-term mortality. Eight hundred forty-five patients were included in the study with complete in-hospital and late mortality data available for all survivors (median follow-up 29.5 months [IQR 16.5 to 48.0]). The mean age (±SD) was 82.3±6.2 years and mean Society of Thoracic Surgery score was 4.0%±3.0%. Patients with LVEDP>12 mm Hg (n = 591, 70%) and LVEDP≤12 mm Hg (n = 254, 30%) had a 6-months mortality rate of 6.8% and 2%, respectively (P=0.004) and a 1-year mortality rate of 10.1% vs 4.9%, respectively (p = 0.017). By multivariable analysis, after-procedural LVEDP>12 mm Hg was independently associated with all-cause mortality (HR 2.45, 95% CI 1.58 to 3.76, p <0.001) during long-term follow-up. In conclusion, elevated after-procedural LVEDP in patients who undewent TAVI is an independent predictor of mortality following TAVI. Further research regarding the use of LVEDP as a tool for after-procedural medical management is warranted.

Для цитирования: Szekely Yishay, Borohovitz Ariel, Hochstadt Aviram, Topilsky Yan, Konigstein Maayan, Halkin Amir, Bazan Samuel, Banai Shmuel, Finkelstein Ariel, Arbel Yaron. Long-term Implications of Post-Procedural Left Ventricular End-Diastolic Pressure in Patients Undergoing Transcatheter Aortic Valve Implantation.. The American journal of cardiology. 2021. DOI: 10.1016/j.amjcard.2021.01.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.