AIMS: Stroke is a major complication after transcatheter aortic valve implantation (TAVI). Although multifactorial, it remains unknown whether the valve deployment system itself has an impact on the incidence of early stroke. We performed a meta- and network analysis to investigate the 30-day stroke incidence of self-expandable (SEV) and balloon-expandable (BEV) valves after transfemoral TAVI.

METHODS AND

RESULTS

Overall, 2723 articles were searched directly comparing the performance of SEV and BEV after transfemoral TAVI, from which 9 were included (3086 patients). Random effects models were used for meta- and network meta-analysis based on a frequentist framework. Thirty-day incidence of stroke was 1.8% in SEV and 3.1% in BEV (risk ratio of 0.62, 95% confidence interval (CI) 0.49-0.80, p = 0.004). Treatment ranking based on network analysis (P-score) revealed CoreValve with the best performance for 30-day stroke incidence (75.2%), whereas SAPIEN had the worst (19.0%). However, network analysis showed no inferiority of SAPIEN compared with CoreValve (odds ratio 2.24, 95% CI 0.70-7.2).

CONCLUSION

Our analysis indicates higher 30-day stroke incidence after transfemoral TAVI with BEV compared to SEV. We could not find evidence for superiority of a specific valve system. More randomized controlled trials with head-to-head comparison of SEV and BEV are needed to address this open question.

Для цитирования: Seppelt Philipp C, Mas-Peiro Silvia, De Rosa Roberta, Dimitriasis Zisis, Zeiher Andreas M, Vasa-Nicotera Mariuca. Thirty-day incidence of stroke after transfemoral transcatheter aortic valve implantation: meta-analysis and mixt-treatment comparison of self-expandable versus balloon-expandable valve prostheses.. Clinical research in cardiology : official journal of the German Cardiac Society. 2020. DOI: 10.1007/s00392-020-01775-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.