MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-024-06044-z

Медицинская библиотека · Clinical oral investigations · 2024

Effect of 850 nm LED irradiation on the alignment of crowded mandibular anterior teeth: a randomized controlled clinical trial.

Farhadian Nasrin, Miresmaeili Amirfarhang, Farhadifard Homa, Banisafar Ziba, Farhadian Maryam, Beiglar Vahid, Ahmadpour Yousef

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

This study aims to determine if intraoral 850 nm LED irradiation could reduce the duration of lower anterior crowding alignment.

METHODS

In a parallel-designed, randomized controlled clinical trial 60 patients with 2 to 6 mm of lower incisor crowding who need non-extraction treatment, were randomly assigned to the intervention and control groups by block randomization (36 females, 24 males, mean age: 19.93 ± 3.05). MBT brackets (0.022 × 0.28-inch) were bonded for both groups and the NiTi wires in sequences were put in place until correction of crowding. The intra-oral LED device with a wavelength of 850 nm and power density of 70 mW/cm2 was used for 5 min per day in the intervention group. The control group did not receive any light. The primary outcome was the duration of crowding correction. The patient's pain according the modified McGill pain questionnaire was the secondary outcome. The Cox regression model was used to compare groups. Mann-Whitney test was used for pain analysis.

RESULTS

The crowding at baseline was the same between the two groups (P > 0.05). Duration of treatment in the intervention group was 104.7 days (95% CI: 95.6 -113.8) and significantly shorter than 161.9 days (95% CI: 151.5 -171.2) in the control group. The control group experienced a significantly higher pain score of 6.8 (95% CI: 6.1-7.5) immediately after archwire placement than the intervention group 5.4 (95% CI: 4.6-6.3).

CONCLUSIONS

Intra-oral LED 850 nm significantly decreased the relieving time of lower incisor crowding by up to 36% and reduced pain experience.

Для цитирования: Farhadian Nasrin, Miresmaeili Amirfarhang, Farhadifard Homa, Banisafar Ziba, Farhadian Maryam, Beiglar Vahid, Ahmadpour Yousef. Effect of 850 nm LED irradiation on the alignment of crowded mandibular anterior teeth: a randomized controlled clinical trial.. Clinical oral investigations. 2024. DOI: 10.1007/s00784-024-06044-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.