MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.108.776120

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2008

Sudden death and defibrillators in transposition of the great arteries with intra-atrial baffles: a multicenter study.

Khairy Paul, Harris Louise, Landzberg Michael J, Fernandes Susan M, Barlow Amanda, Mercier Lise-Andrée, Viswanathan Sangeetha, Chetaille Philippe, Gordon Elaine, Dore Annie, Cecchin Frank

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Transposition of the great arteries with intra-atrial baffle repair is among the congenital heart defects at highest risk of sudden death. Little is known about mechanisms of sudden death and the role of implantable cardioverter defibrillators.

METHODS AND

RESULTS

We conducted a multicenter cohort study in patients with transposition of the great arteries to determine actuarial rates of implantable cardioverter defibrillator shocks, identify risk factors, assess underlying arrhythmias, and characterize complications. Overall, 37 patients (age, 28.0+/-7.6 years; 89.2% male) were enrolled from 7 sites. Implantable cardioverter defibrillators were implanted for primary prevention in 23 (62.1%) patients and secondary prevention in 14 patients (37.8%). Annual rates of appropriate shocks were 0.5% and 6.0% in primary and secondary prevention, respectively (P=0.0366). Independent predictors were a secondary prevention indication (hazard ratio, 18.0; P=0.0341) and lack of beta-blockers (hazard ratio, 16.7; P=0.0301). In patients with appropriate shocks, intracardiac electrograms documented supraventricular tachycardia preceding or coexisting with ventricular tachycardia in 50%. No patient with inducible ventricular tachycardia received an appropriate shock in comparison with 37.5% of noninducible patients (P=0.0429). Inappropriate shocks occurred in 6.6% per year, more so in patients of lesser weight (hazard ratio, 0.91 per kg; P=0.0168). Additionally, 14 patients (37.8%) experienced complications: 5 (13.5%) acute, 1 (2.7%) late generator related, and 12 (32.4%) late lead related.

CONCLUSIONS

In patients with transposition of the great arteries, high rates of appropriate shocks are noted in secondary but not primary prevention. Supraventricular arrhythmias may be implicated in the etiology of ventricular tachyarrhythmias; beta-blockers seem protective, and inducible ventricular tachycardia does not seem to predict future events. Inappropriate shocks and late lead-related complications are common.

Для цитирования: Khairy Paul, Harris Louise, Landzberg Michael J, Fernandes Susan M, Barlow Amanda, Mercier Lise-Andrée, Viswanathan Sangeetha, Chetaille Philippe, Gordon Elaine, Dore Annie, Cecchin Frank. Sudden death and defibrillators in transposition of the great arteries with intra-atrial baffles: a multicenter study.. Circulation. Arrhythmia and electrophysiology. 2008. DOI: 10.1161/circep.108.776120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.