OBJECTIVE

To investigate the diagnostic performance of bronchoscopy in patients with coronavirus disease 2019 infection.

METHODS

The systematic review was conducted in April 2021 and comprised search of published articles and preprint servers for original articles assessing diagnostic performance of bronchoscopy in patients with suspected coronavirus disease 2019 infection. The primary outcome of interest was diagnostic sensitivity of bronchoalveolar lavage in the patients. The quality of each study was assessed using the Quality Assessment, Data Abstraction and Synthesis-2 tool.

RESULTS

Of the 29 full-text articles assessed for eligibility, 4(13.8%) were included collectively comprising 209 patients who had undergone bronchoalveolar lavage. Mean sensitivity of bronchoalveolar lavage was 83.5% ± 10.63 (range: 68.2-940%). Overall, the 4 studies had an unclear or low risk of bias.

CONCLUSIONS

Limited data suggested that bronchoscopy with bronchoalveolar lavage did not have reliably higher diagnostic sensitivity than that reported for either nasopharyngeal or oropharyngeal swabs.

Для цитирования: Raza Hussain Ahmed, Raja Mohummad Hassan Raza, Bain Paul Arthur, Bedi Harmeet, Salam Rehana, Jamil Bushra, Shafiq Majid. Diagnostic value of bronchoscopy in Sars-Cov-2 infection: A systematic review.. JPMA. The Journal of the Pakistan Medical Association. 2023. DOI: 10.47391/jpma.5668.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.