MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1051/ject/2023031

Медицинская библиотека · The journal of extra-corporeal technology · 2023

Minimal invasive extracorporeal circulation an alternative to ECMO in ventricular tachycardia ablation.

Condello Ignazio

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The advantages of mechanical assistance during ventricular tachycardia (VT) ablation have not been clinically demonstrated. We propose and discuss a technique, set up by us, that makes use of minimally invasive extra-corporeal circulation (MiECC) type III associated with a venous reservoir system, which allows complete cardiac flow support and blood oxygenation as well as hemodynamic stability during long-lasting procedures.

METHODS

We present a retrospective case series of ten patients with valvular heart disease and unresponsive Ventricular Tachycardia (VT) who underwent VT ablation with MiECC support. The mean age of the patients was 72 ± 8 years and the left ventricular ejection fraction was 36 ± 12%. All patients underwent a clinical evaluation to identify the cause of VT unresponsiveness (e.g., ischemic heart disease).

RESULTS

A total of 140 min, the following parameters were evaluated and recorded for 140 min. Central venous pressure (CVP) was used to evaluate excess volume. During the first 5 min, the mean was 15 mmHg, with a pump flow of 1.5 L/min and a mean systemic arterial pressure of 100 mmHg while setting up the circulation support. Following drainage in a volumetric bag of 1 L of blood, CVP was reduced to a value of 5 mmHg with a flow rate of 5 L/min and a mean systemic arterial pressure of 65 mmHg. In the case of small and low-weight patients our "1 L protocol" can be modified.

CONCLUSIONS

In this preliminary retrospective case series, the MiECC type III system may represent the ideal support system during VT ablation, and further studies are needed to support this preliminary report.

Для цитирования: Condello Ignazio. Minimal invasive extracorporeal circulation an alternative to ECMO in ventricular tachycardia ablation.. The journal of extra-corporeal technology. 2023. DOI: 10.1051/ject/2023031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.