MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8167.2008.01145.x

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2008

Automatic 3D mapping of complex fractionated atrial electrograms (CFAE) in patients with paroxysmal and persistent atrial fibrillation.

Wu Jinjin, Estner Heidi, Luik Armin, Ucer Ekrem, Reents Tilko, Pflaumer Andreas, Zrenner Bernhard, Hessling Gabriele, Deisenhofer Isabel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Complex fractionated atrial electrograms (CFAE) are a possible target for atrial fibrillation (AF) ablation and can be visualized in three-dimensional (3D) mapping systems with specialized software.

OBJECTIVE

To use the new CFAE software of CartoXP (Biosense Webster, Diamond Bar, CA, USA) for analysis of spatial distribution of CFAE in paroxysmal and persistent AF.

METHODS

We included 16 consecutive patients (6 females; mean 59.3 years) with AF (6 paroxysmal and 10 persistent) undergoing AF ablation. Carto maps of left atrium (LA) were reconstructed. Using the new CFAE software, the degree of local electrogram fractionation was displayed color-coded on the map surface. LA was divided into four regions: anterior wall, inferior wall, septum, and pulmonary veins (PV). The relationship among regions with CFAE visualized and CFAE ablation regions (persistent AF only) was analyzed retrospectively.

RESULTS

In paroxysmal and persistent AF, CFAE were observed in all four LA regions. In paroxysmal AF, the density of CFAE around the PV was significantly higher than in other regions (P < 0.05) and higher than in persistent AF (P < 0.05). In persistent AF, CFAE were evenly distributed all over the LA. Of 40 effective ablation sites with significant AF cycle length prolongation, 33 (82.5%) were judged retrospectively by CFAE map as CFAE sites.

CONCLUSION

CFAE software can visualize the spatial distribution of CFAE in AF. CFAE in persistent AF were observed in more regions of LA compared to paroxysmal AF in which CFAE concentrated on the PV. Automatically detected CFAE match well with ablation sites targeted by operators.

Для цитирования: Wu Jinjin, Estner Heidi, Luik Armin, Ucer Ekrem, Reents Tilko, Pflaumer Andreas, Zrenner Bernhard, Hessling Gabriele, Deisenhofer Isabel. Automatic 3D mapping of complex fractionated atrial electrograms (CFAE) in patients with paroxysmal and persistent atrial fibrillation.. Journal of cardiovascular electrophysiology. 2008. DOI: 10.1111/j.1540-8167.2008.01145.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.