DOI 10.1016/j.ijcard.2005.11.108
DC cardioversion of persistent atrial fibrillation: a comparison of two protocols.
Аннотация
BACKGROUND
Current guidelines for transthoracic direct-current cardioversion (DCCV) of atrial fibrillation (AF) recommend a step-up energy protocol. The aim of this study was to compare such a protocol with a protocol involving a high initial energy shock, anteroposterior paddle position and reversal of shock polarity, on cardioversion efficacy, total energy delivery, use of sedation and patient tolerability.
METHODS
261 patients (mean age 71+/-10 years, 62% male) referred for elective DCCV of persistent AF were enrolled. Patients were randomised to either protocol A: (1) 200 J anteroapical, (2) 360 J anteroapical, (3) 360 J anteroposterior; or protocol B: (1) 360 J anteroapical, (2) 360 J anteroposterior, and (3) 360 J posteroanterior. All procedures were performed under sedation with intravenous diazepam.
RESULTS
Protocol B improved shock success rates (protocol A first shock success rate=42%, protocol B=68%, p<0.001; protocol A second shock success rate=72%, protocol B 86%, p=0.006; protocol A third shock success rate=83%, protocol B=92%, p=0.03) and required fewer shocks to achieve sinus rhythm (1.3+/-0.6) compared with protocol A (1.6+/-0.7, p<0.001). There were no differences in cumulative energy used (protocol A 473+/-286 J, protocol B 436+/-273 J, p=0.24) or sedation requirements (protocol A diazepam 22.1+/-9.0 mg, protocol B 21.7+/-8.9 mg, p=0.75). Both protocols were equally well tolerated by patients.
CONCLUSION
High initial energy increased success rates and decreased the number of shocks but resulted in similar cumulative energy delivery, sedation use and patient tolerability compared with a conventional step-up protocol.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.