MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/joor.13651

Медицинская библиотека · Journal of oral rehabilitation · 2024

Comparison of force profiles from two musculoskeletal palpation methods: A methodological study.

Pillai Rajath Sasidharan, Kothari Simple Futarmal, Svensson Peter, Castrillon Eduardo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) protocol recommends a 5 s and 1 kg force dynamic palpation around the lateral condylar pole of the temporomandibular joint. However, the accuracy and precision of the generated force are not known.

OBJECTIVE

To assess and compare the force profiles generated from dynamic palpation manually and using a palpometer, based on the forces and time recommendations suggested by the DC/TMD protocol.

METHODS

Nineteen healthy adults applied forces of 0.5 kg, 1.0 kg and 2.0 kg on a calibrated force sensor in a circular motion within target times of 2 s and 5 s. Participants used their right index finger for manual palpation and a calibrated palpometer for device-assisted palpation. Ten repetitions of each target force at both target times were applied. Time taken to complete each application was recorded. Repeated measures analysis of variance was used for analysis of accuracy measured as the relative difference between targeted force and actual force values and precision measured as the coefficient of variation (CV) within the 10 repeated measurements.

RESULTS

Accuracy was significantly lower (better) and precision higher (lower CV) with the palpometer than with manual palpation (p < .001). There were significant differences in accuracy and precision between the different forces but not palpation times. Most participants could not achieve the target times and tended to be faster, irrespective of the palpation method (p > .063).

CONCLUSION

A palpometer is a more accurate and precise palpation method for dynamic force assessment compared to manual palpation; however, it remains difficult to standardize the palpation duration.

Для цитирования: Pillai Rajath Sasidharan, Kothari Simple Futarmal, Svensson Peter, Castrillon Eduardo. Comparison of force profiles from two musculoskeletal palpation methods: A methodological study.. Journal of oral rehabilitation. 2024. DOI: 10.1111/joor.13651.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.