MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cen.14920

Медицинская библиотека · Clinical endocrinology · 2023

Late-night salivary cortisol cut-offs for diagnosis of Cushing syndrome using second-generation electrochemiluminescence immunoassay kits.

Goyal Alpesh, Attri Bhawna, Gupta Yashdeep, Kalaivani Mani, Jyotsna Viveka P, Tandon Nikhil

СтатьяПеревод пока не подготовлен

Аннотация

CONTEXT: Late-night salivary cortisol (LNSC) is a simple and reliable screening test for Cushing syndrome (CS). With improved analytical performance of the current second-generation electrochemiluminescence immunoassay (ECLIA; Elecsys Cortisol-II; Roche Diagnostics), there is a need to revisit the LNSC cut-offs, especially in a South-Asian population.

OBJECTIVE

To derive LNSC cut-offs for diagnosis of CS using second-generation ECLIA kits.

DESIGN

Diagnostic accuracy study.

METHODS

We prospectively recruited 155 controls aged 18-60 years, including, normal-weight (body mass index [BMI] < 25 kg/m2 and no hypertension or diabetes [n = 53]) and overweight/obese (BMI 25-30 kg/m2 and hypertension and/or diabetes [n = 52] or BMI ≥ 30 kg/m2 with/without comorbidities [n = 50]) participants. All participants submitted LNSC samples collected at home; overweight/obese controls additionally underwent dexamethasone suppression test to exclude CS. We also reviewed records of adults with endogenous CS (cases, n = 92) and a valid LNSC result using the same method.

RESULTS

The 95th percentile for LNSC in controls was 6.76 nmol/L. The mean ± SD LNSC levels were 40.47 ± 49.63 nmol/L in cases and 3.37 ± 1.18 nmol/L in controls (p < 0.001). Receiver operating characteristic (ROC) analysis showed excellent diagnostic performance of LNSC for CS, with area under curves (AUCs) of 0.994 (cases vs. all controls) and 0.993 (cases vs. overweight/obese controls), respectively. The best diagnostic performance was achieved at cut-offs ≥6.73 nmol/L (sensitivity: 97.8%, specificity: 94.8%) and ≥7.26 nmol/L (sensitivity: 97.8%, specificity: 95.1%), respectively.

CONCLUSIONS

LNSC measured using second-generation ECLIA demonstrated high diagnostic accuracy for CS. Based on this study, we propose a LNSC cutoff ≥6.73 nmol/L to diagnose CS.

Для цитирования: Goyal Alpesh, Attri Bhawna, Gupta Yashdeep, Kalaivani Mani, Jyotsna Viveka P, Tandon Nikhil. Late-night salivary cortisol cut-offs for diagnosis of Cushing syndrome using second-generation electrochemiluminescence immunoassay kits.. Clinical endocrinology. 2023. DOI: 10.1111/cen.14920.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.