Transcranial color-coded duplex sonography for detection of distal internal carotid artery stenosis.
Аннотация
BACKGROUND AND PURPOSE: Gradation of high-grade intracranial internal carotid artery (ICA) stenosis poses a challenge to noninvasive neurovascular imaging, which seems critical for angioplasty in the ICA segments C1 and C5. We investigated cutoff values of intracranial ICA stenosis for transcranial color-coded sonography (TCCS) and compared this method with the "gold standard," digital subtraction angiography (DSA).
MATERIALS AND
METHODS
Forty patients (mean age, 58.9 +/- 13.8 years) with intracranial ICA lesions were prospectively examined by using TCCS and DSA. Two standard TCCS coronal imaging planes were used to evaluate the intracranial ICA. In addition, a control group of 128 volunteers without cerebrovascular disease (mean age, 48.8 +/- 15.9 years) was investigated to establish standard velocity values.
RESULTS
DSA confirmed 96 stenoses and 8 occlusions of the intracranial ICA in the study population. In 9% and 7% of cases, stenosis confined to the C1 or C5 segment was >50% and 70%, respectively. Receiver-operating curves demonstrated cutoff values for >70% stenosis in C1 when the peak systolic velocity (PSV) was >200 cm/s (specificity, 100%; sensitivity, 71%) or the C1/submandibular ICA index was >3 (specificity, 93%; sensitivity, 86%).
CONCLUSIONS
TCCS is a reliable adjunctive method to detect and quantify significant stenosis of the intracranial ICA. The assessment of the C1/ICA index and peak systolic velocities maximizes the diagnostic accuracy of C1 stenosis to >70% when extracranial ICA stenosis coexists. Further studies need to be performed to compare the diagnostic accuracies of MR angiography and TCCS with that of DSA.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.