MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000015602

Медицинская библиотека · Medicine · 2019

Proposed safe apnea test using positive end-expiratory pressure valve and short-term blood gas analysis: Observational study.

Park Jin, Lee Young-Joo, Hong Kyung Sook

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

The apnea test is an essential examination for the determination of brain death; however, hypotension, hypoxemia, and other complications during the apnea test can affect the stability of brain-dead patients, as well as organ function for recipients. Therefore, it is necessary to establish standard guidelines for apnea testing.The modified apnea test (MAT) comprises delivery of 100% oxygen through the endotracheal tube connected to manual resuscitator (Ambu bag) with the positive end-expiratory pressure (PEEP) valve after disconnection of the mechanical ventilator for maintenance of PEEP. Forty-nine instances of the conventional apnea test (CAT) were performed in 25 brain-dead patients; 77 instances of the MAT were performed in 39 brain-dead patients.The mean duration of the apnea test was 3.5 ± 1.4 minutes in the CAT group and 3.0 ± 1.2 minutes in the MAT group. There were no significant changes in PaCO2, PaO2, or pH between the CAT and MAT groups (P = .341, .593, and .503, respectively). In overweight patients (body mass index ≥ 23 kg/m), MAT prevented dramatic reductions in PaO2 and SaO2 (P < .05 for both). In the patients who had hypoxic brain injury due to hanging, differences in PaO2 and SaO2 in the MAT group were significantly smaller than in the CAT group (P < .05).Although MAT, which was invented to maintain PEEP, was not efficient for all brain-dead patients, it could be helpful in selected patient groups, such as overweight patients or those who had hypoxic injury due to hanging. And clinicians should consider short-term apnea test to avoid unnecessarily prolonged hypoxemia.

Для цитирования: Park Jin, Lee Young-Joo, Hong Kyung Sook. Proposed safe apnea test using positive end-expiratory pressure valve and short-term blood gas analysis: Observational study.. Medicine. 2019. DOI: 10.1097/md.0000000000015602.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.