MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s004360050465

Медицинская библиотека · Parasitology research · 1998

Development of an enzyme-linked immunosorbent assay for detection of antibodies to Babesia bigemina in cattle.

Molloy J B, Bowles P M, Jeston P J, Bruyeres A G, Bowden J M, Bock R E, Jorgensen W K, Blight G W, Dalgliesh R J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Monoclonal antibodies, directed against a 58-kDa Babesia bigemina merozoite antigen that reacted strongly with immune sera from experimentally and naturally infected cattle in Western blots, were used to develop a competitive-inhibition enzyme-linked immunosorbent assay (ELISA). As based on the testing of 70 antibody-positive sera from experimentally infected cattle and 166 antibody-negative sera collected in non-endemic areas of Australia, the sensitivity and specificity of the ELISA were 95.7% and 97.0%, respectively. In sequential sera collected from six calves during the course of experimental B. bigemina infections the ELISA detected seroconversion at about 10 days post-inoculation. The specificity of the ELISA was not affected by the presence of antibodies to B. bovis, Anaplasma marginale or Theileria buffeli. In 42 sera from cattle experimentally infected with B. bovis but negative for B. bigemina the specificity of the ELISA was 95.2%. The use of a competitive-inhibition ELISA format detecting only antibody directed against a single epitope on the 58-kDa antigen appears to have overcome many of the specificity problems that have plagued serological tests for B. bigemina in the past. The test should be useful for epidemiology studies, particularly in areas where B. bovis and B. bigemina have overlapping distributions.

Для цитирования: Molloy J B, Bowles P M, Jeston P J, Bruyeres A G, Bowden J M, Bock R E, Jorgensen W K, Blight G W, Dalgliesh R J. Development of an enzyme-linked immunosorbent assay for detection of antibodies to Babesia bigemina in cattle.. Parasitology research. 1998. DOI: 10.1007/s004360050465.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.