MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1101/2025.03.05.25323327

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2025

Remote exercise-induced sweat chloride measurements using a wearable microfluidic sticker in cystic fibrosis patients.

Nelson Rachel S, Grossman Margaret G, Klug Zasu M, Calamari Mia, Donayre Alvaro, Cybulski Thaddeus, Schooley Jared, Griffith Garett J, Corcos Daniel M, Wright Donald E, Wallace Jessica C, Yang Da Som, Wright John A, Rogers John A, Ghaffari Roozbeh, Aranyosi A J, Jain Manu

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold-standard for sweat chloride, but this technique is cumbersome and not suitable for remote settings. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here we conducted clinical studies characterizing the accuracy of the CF Patch compared to pilocarpine-induced sweat measurements using chloridometry and tested the feasibility of exercise-induced sweat chloride measurements in PwCF. The CF Patch demonstrated strong correlations compared to sweat chloride measured by chloridometry across clinic and remote settings and detected greater day-to-day sweat chloride variability in PwCF on CFTR modulators than healthy volunteers. These findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens.

Для цитирования: Nelson Rachel S, Grossman Margaret G, Klug Zasu M, Calamari Mia, Donayre Alvaro, Cybulski Thaddeus, Schooley Jared, Griffith Garett J, Corcos Daniel M, Wright Donald E, Wallace Jessica C, Yang Da Som, Wright John A, Rogers John A, Ghaffari Roozbeh, Aranyosi A J, Jain Manu. Remote exercise-induced sweat chloride measurements using a wearable microfluidic sticker in cystic fibrosis patients.. medRxiv : the preprint server for health sciences. 2025. DOI: 10.1101/2025.03.05.25323327.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.