MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3802/jgo.2023.34.e31

Медицинская библиотека · Journal of gynecologic oncology · 2023

The value of PET/CT for cytoreductive surgery selection in recurrent ovarian carcinoma.

Nunes Rafael Leite, Teixeira Flávio Rodrigues, Diniz Thiago Pereira, Faloppa Carlos Chaves, Mantoan Henrique, da Costa Alexandre Andre Balieiro Anastacio, Baiocchi Glauco

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the value of positron emission tomography/computed tomography (PET/CT) in predicting no residual disease (NRD) after secondary cytoreductive surgery (SCS) compared with MSK criteria, the iMODEL, and the AGO score.

METHODS

We analyzed 112 patients with platinum-sensitive ovarian carcinoma who underwent SCS. We excluded patients for whom PET/CT was not performed, those without sufficient data, and who received chemotherapy before SCS. Ultimately, 69 patients were included.

RESULTS

Variables that correlated with NRD were peritoneal carcinomatosis index (odds ratio [OR]=0.91; 95% confidence interval [CI]=0.83-0.99; p=0.044), European Cooperative Oncology Group Performance Status (ECOG) 0 (OR=8.0; 95% CI=1.34-47.5; p=0.022), and ≤2 lesions by PET/CT (OR=4.36; 95% CI=1.07-17.7; p=0.039). Of the patients with ≤2 lesions by PET/CT, 48 (92.3%) underwent complete SCS. The sensitivity, positive predictive value, negative predictive value, and accuracy of PET/CT for NRD were 85.7%, 92.3%, 33.3%, and 81.2%, respectively. NRD was achieved after fulfilling the MSK criteria, iMODEL and AGO Score in 89.1%, 88.1% and 85.9%, respectively. The accuracy of the MSK criteria, iMODEL, and AGO score in predicting NRD was 87%, 83.3%, and 77.3%, respectively. The PET/CT findings agreed well with the AGO score and iMODEL. The addition of PET/CT to these models increased the NRD rates (92.2%, 91.8%, and 89.4% for MSK+PET/CT, iMODEL+PET/CT, and AGO+PET/CT, respectively), but lowered their accuracy.

CONCLUSION

We observed NRD in 92.3% of patients with ≤2 lesions by PET/CT, with an accuracy of 81.2%. PET/CT did not increase the accuracy of the MSK criteria, iMODEL, or AGO score models.

Для цитирования: Nunes Rafael Leite, Teixeira Flávio Rodrigues, Diniz Thiago Pereira, Faloppa Carlos Chaves, Mantoan Henrique, da Costa Alexandre Andre Balieiro Anastacio, Baiocchi Glauco. The value of PET/CT for cytoreductive surgery selection in recurrent ovarian carcinoma.. Journal of gynecologic oncology. 2023. DOI: 10.3802/jgo.2023.34.e31.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.