MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0000000000002824

Медицинская библиотека · Journal of orthopaedic trauma · 2024

Clinical and Radiographic Results After Treatment of Traumatic Syndesmotic Instability Using a Novel Screw-Suture Syndesmotic Fixation Device.

Shaath M Kareem, Williams Warren A, Kelly John J, Garrett Christopher H, Munro Mark W, Avilucea Frank R, Langford Joshua R, Haidukewych George J

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The objective of this study was to report early outcomes of a novel screw-suture syndesmotic device compared with suture button fixation devices when treating traumatic syndesmotic instability.

DESIGN

Retrospective chart review.

SETTING

Single academic Level 1 Trauma Center.

PATIENT SELECTION CRITERIA: All adult patients who had syndesmotic fixation with the novel device [novel syndesmotic repair implant (NSRI) group] compared with a suture button device (SB group) between January 2018 and December 2022.

OUTCOME MEASURES AND COMPARISONS: Medial clear space and tibiofibular overlap measurements were compared immediately postoperatively and at the final follow-up. Patients were followed for a minimum of 1 year or skeletal healing.

RESULTS

Fifty-nine patients (25 female) with an average age of 47 years (range 19-78 years) were in the NSRI group compared with 52 patients (20 female) with an average age of 41 years (range 18-73 years) in the SB group. There were no significant differences when comparing body mass index, diabetes, or smoking status between groups (P > 0.05). There was no difference when comparing the postoperative and final medial clear space measurements in the NSRI group compared with the SB group (P = 0.86; 95% confidence interval, -0.32 to 0.27). There was no difference when comparing the postoperative and final tibiofibular overlap measurements in the NSRI group compared with the SB group (P = 0.79; 95% confidence interval, -0.072 to 0.09). There were 3 cases of implant removal in the NSRI group compared with 2 in the SB group (P = 0.77). There was 1 failure in the NSRI group and none in the SB group. The remaining patients were all fully ambulatory at the final follow-up (P = 0.35).

CONCLUSIONS

A novel screw-suture syndesmotic implant provides the fixation of a screw, and the flexibility of a suture had similar radiographic outcomes compared with suture button fixation devices in treating ankle syndesmotic instability.

LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Shaath M Kareem, Williams Warren A, Kelly John J, Garrett Christopher H, Munro Mark W, Avilucea Frank R, Langford Joshua R, Haidukewych George J. Clinical and Radiographic Results After Treatment of Traumatic Syndesmotic Instability Using a Novel Screw-Suture Syndesmotic Fixation Device.. Journal of orthopaedic trauma. 2024. DOI: 10.1097/bot.0000000000002824.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.