MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.14117

Медицинская библиотека · Veterinary surgery : VS · 2024

Ex vivo biomechanical evaluation of tissue construct strength in an equine colopexy model.

Gaitan Hannah M, Mudge Margaret C, Litsky Alan S, Arruda Andreia G, Gardner Alison K

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare strength of left paramedian colopexies using various techniques in equine ex vivo models.

STUDY

DESIGN

Experimental study.

SAMPLE POPULATION: Equine cadavers euthanized for nongastrointestinal pathology (36 specimens derived from 9 horses).

METHODS

Colopexies were performed after euthanasia. Suture pattern (horizontal mattress vs. cruciate) and incorporation of dorsal sheath of the rectus abdominis (partial-thickness) versus incorporation of dorsal and ventral sheath of the rectus abdominis (full-thickness) were evaluated. Single cycle load to failure, work to peak load, stiffness, and mode of failure of colopexy tissue constructs were assessed.

RESULTS

Mean load to failure of all constructs ranged from 102.26 to 166.38 N. Partial-thickness bites demonstrated a mean load to failure and standard deviation (SD) of 111.91 (35.88) N and 102.26 (30.06) N (p < .05) which was significantly lower than the mean and SD of full-thickness bites (166.3 [72.42] N and 163.21 [51.40 N]), respectively. All full-thickness bites regardless of suture pattern and over half of partial-thickness bites failed at the colonic wall. There was no significant difference in load to failure compared to mode of failure.

CONCLUSION

A stronger colopexy was achieved with a full-thickness bite regardless of the suture pattern. The most common mode of failure was the colon wall.

CLINICAL SIGNIFICANCE: Incorporating ventral and dorsal fascia of the rectus abdominus provided a stronger colopexy structure, which may necessitate a second incision or subcutaneous palpation of the needle when performing a colopexy. The lateral band of the colon failed in most constructs (77%) regardless of technique, which could weaken the colonic wall and risk colonic rupture.

Для цитирования: Gaitan Hannah M, Mudge Margaret C, Litsky Alan S, Arruda Andreia G, Gardner Alison K. Ex vivo biomechanical evaluation of tissue construct strength in an equine colopexy model.. Veterinary surgery : VS. 2024. DOI: 10.1111/vsu.14117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.