MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10856-020-06452-z

Медицинская библиотека · Journal of materials science. Materials in medicine · 2020

Histopathologic response after hydrophilic polyethylene glycol-coating stent and hydrophobic octadecylthiol-coating stent implantations in porcine coronary restenosis model.

Choe Jeong Cheon, Park Jong Ha, Lee Han Cheol, Park Tae Sik, Ahn Jinhee, Park Jin Sup, Lee Hye Won, Oh Jun-Hyok, Choi Jung Hyun, Cha Kwang Soo, Yim Changyong, Jeon Sangmin

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Device-related problems of drug-eluting stents, including stent thrombosis related to antiproliferative drugs and polymers, can cause adverse events such as inflammation and neointimal hyperplasia. Stent surface modification, wherein the drug and polymer are not required, may overcome these problems. We developed hydrophilic polyethylene glycol (PEG)-coating and hydrophobic octadecylthiol (ODT)-coating stents without a drug and polymer and evaluated their histopathologic response in a porcine coronary restenosis model. PEG-coating stents (n = 12), bare-metal stents (BMS) (n = 12), and ODT-coating stents (n = 10) were implanted with oversizing in 34 porcine coronary arteries. Four weeks later, the histopathologic response, arterial injury, inflammation, and fibrin scores were analyzed. A p value < 0.05 was considered statistically significant. There were significant differences in the internal elastic lamina area, lumen area, neointimal area, percent area of stenosis, arterial injury score, inflammation score, and fibrin score among the groups. Compared to the BMS or ODT-coating stent group, the PEG-coating stent group had significantly increased internal elastic lamina and lumen area (all p < 0.001) and decreased neointimal area and percent area of stenosis (BMS: p = 0.03 and p < 0.001, respectively; ODT-coating: p = 0.013 and p < 0.001, respectively). Similarly, the PEG-coating group showed significantly lower inflammation and fibrin scores than the BMS or ODT-coating groups (BMS: p = 0.013 and p = 0.007, respectively; ODT-coating: p = 0.014 and p = 0.008, respectively). In conclusion, hydrophilic PEG-coating stent implantation was associated with lower inflammatory response, decreased fibrin deposition, and reduced neointimal hyperplasia than BMS or hydrophobic ODT-coating stent implantation in the porcine coronary restenosis model.

Для цитирования: Choe Jeong Cheon, Park Jong Ha, Lee Han Cheol, Park Tae Sik, Ahn Jinhee, Park Jin Sup, Lee Hye Won, Oh Jun-Hyok, Choi Jung Hyun, Cha Kwang Soo, Yim Changyong, Jeon Sangmin. Histopathologic response after hydrophilic polyethylene glycol-coating stent and hydrophobic octadecylthiol-coating stent implantations in porcine coronary restenosis model.. Journal of materials science. Materials in medicine. 2020. DOI: 10.1007/s10856-020-06452-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.