Scientific reports · 2020
Comparison of overexpansion capabilities and thrombogenicity at the side branch ostia after implantation of four different drug eluting stents.
Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gasior Pawel, Lu Shengjie, Ng Chen Koon Jaryl, Toong Wee Yee Daniel, Wong En Hou Philip, Foin Nicolas, Kedhi Elvin, Wojakowski Wojciech, Ang Hui Ying
Аннотация
Interventions in bifurcation lesions often requires aggressive overexpansion of stent diameter in the setting of long tapering vessel segment. Overhanging struts in front of the side branch (SB) ostium are thought to act as a focal point for thrombi formation and consequently possible stent thrombosis. This study aimed to evaluate the overexpansion capabilities and thrombogenicity at the SB ostia after implantation of four latest generation drug-eluting stents (DES) in an in-vitro bifurcation model. Four clinically available modern DES were utilized: one bifurcation dedicated DES (Bioss LIM C) and three conventional DES (Ultimaster, Xience Sierra, Biomime). All devices were implanted in bifurcation models with proximal optimization ensuring expansion before perfusing with porcine blood. Optical coherence tomography (OCT), immunofluorescence (IF) and scanning electron microscope analysis were done to determine thrombogenicity and polymer coating integrity at the over-expanded part of the stents. Computational fluid dynamics (CFD) was performed to study the flow disruption. OCT (p = 0.113) and IF analysis (p = 0.007) demonstrated lowest thrombus area at SB ostia in bifurcation dedicated DES with favorable biomechanical properties compared to conventional DES. The bifurcated DES also resulted in reduced area of high shear rate and maximum shear rate in the CFD analysis. This study demonstrated numerical differences in terms of mechanical properties and acute thrombogenicity at SB ostia between tested devices.
Предметные рубрики MeSH
Angioplasty, Balloon, CoronaryAnimalsBiomechanical PhenomenaCoronary StenosisCoronary ThrombosisCoronary VesselsDrug-Eluting StentsFluorescent Antibody TechniqueHemodynamicsHumansHydrodynamicsIn Vitro TechniquesMicroscopy, Electron, ScanningModels, CardiovascularProsthesis DesignSelf Expandable Metallic StentsSwineThrombosisTomography, Optical Coherence