Sartori Paola Vincenza, Romano Fabrizio, Uggeri Fabio, Colombo Giovanni, Caprotti Roberto, Giannattasio Cristina, Scotti Mauro Alessandro, Delitala Alberto, Prada Massimo, Uggeri Franco
Аннотация
PURPOSE: In literature, few papers compare different hemostatic devices in laparoscopic adrenalectomy. This sequential cohort study analyzes the outcomes of laparoscopic adrenalectomy performed by different hemostatic instruments, to evaluate if any of them has any advantage over the other and as secondary endpoints, the impact of body mass index (BMI) and tumor size on the indication, and the outcome of laparoscopic adrenalectomy.
METHODS: Forty-six patients, aged 54.6 +/- 46 years, underwent laparoscopic adrenalectomy over 5 years. Mean BMI was 27 +/- 4.8 kg/m(2). Twenty-four patients had a left tumor, and 22 had a right one. Patients were divided into two groups according to the hemostatic device: Ultracision was used in 26 patients, and Ligasure was used in 20. Groups were well matched for histology, tumor size and site, BMI, gender, and age.
RESULTS: Mean operating time was 126.5 +/- 52 min, blood losses were 101 +/- 169 mm, conversion rate was 6.5%, morbidity was 26%, and hospitalization was 5.3 +/- 2.5 days. Groups did not differ for surgical time, blood losses, complications, and conversion rate; BMI and length of surgery were not related. Tumor side and size did not affect surgical time, regardless of the hemostatic tool. Patients submitted to left adrenalectomy bled more (p = 0.007) and had more complications (p = 0.016) than those undergone operation on the right side.
CONCLUSIONS: Obesity (BMI > 30) and large masses do not contraindicate laparoscopic adrenalectomy. Left adrenalectomies bleed more and have a higher morbidity. Hemostatic device choice is up to surgeon's preference.
METHODS: Forty-six patients, aged 54.6 +/- 46 years, underwent laparoscopic adrenalectomy over 5 years. Mean BMI was 27 +/- 4.8 kg/m(2). Twenty-four patients had a left tumor, and 22 had a right one. Patients were divided into two groups according to the hemostatic device: Ultracision was used in 26 patients, and Ligasure was used in 20. Groups were well matched for histology, tumor size and site, BMI, gender, and age.
RESULTS: Mean operating time was 126.5 +/- 52 min, blood losses were 101 +/- 169 mm, conversion rate was 6.5%, morbidity was 26%, and hospitalization was 5.3 +/- 2.5 days. Groups did not differ for surgical time, blood losses, complications, and conversion rate; BMI and length of surgery were not related. Tumor side and size did not affect surgical time, regardless of the hemostatic tool. Patients submitted to left adrenalectomy bled more (p = 0.007) and had more complications (p = 0.016) than those undergone operation on the right side.
CONCLUSIONS: Obesity (BMI > 30) and large masses do not contraindicate laparoscopic adrenalectomy. Left adrenalectomies bleed more and have a higher morbidity. Hemostatic device choice is up to surgeon's preference.
Предметные рубрики MeSH
Adrenal Gland NeoplasmsAdrenalectomyAdultAgedAnalysis of VarianceBlood Loss, SurgicalBody Mass IndexCohort StudiesContraindicationsFemaleHemostatic TechniquesHumansItalyLaparoscopyLength of StayMaleMiddle AgedObesityRetrospective StudiesStatistics, NonparametricTime FactorsTreatment OutcomeUltrasonic Therapy