Медицинская библиотека · Journal of hepatology · 2017

Validity criteria for the diagnosis of fatty liver by M probe-based controlled attenuation parameter.

Wong Vincent Wai-Sun, Petta Salvatore, Hiriart Jean-Baptiste, Cammà Calogero, Wong Grace Lai-Hung, Marra Fabio, Vergniol Julien, Chan Anthony Wing-Hung, Tuttolomondo Antonino, Merrouche Wassil, Chan Henry Lik-Yuen, Le Bail Brigitte, Arena Umberto, Craxì Antonio, de Lédinghen Victor

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND & AIMS: Controlled attenuation parameter (CAP) can be performed together with liver stiffness measurement (LSM) by transient elastography (TE) and is often used to diagnose fatty liver. We aimed to define the validity criteria of CAP.

METHODS

CAP was measured by the M probe prior to liver biopsy in 754 consecutive patients with different liver diseases at three centers in Europe and Hong Kong (derivation cohort, n=340; validation cohort, n=414; 101 chronic hepatitis B, 154 chronic hepatitis C, 349 non-alcoholic fatty liver disease, 37 autoimmune hepatitis, 49 cholestatic liver disease, 64 others; 277 F3-4; age 52±14; body mass index 27.2±5.3kg/m2). The primary outcome was the diagnosis of fatty liver, defined as steatosis involving ≥5% of hepatocytes.

RESULTS

The area under the receiver-operating characteristics curve (AUROC) for CAP diagnosis of fatty liver was 0.85 (95% CI 0.82-0.88). The interquartile range (IQR) of CAP had a negative correlation with CAP (r=-0.32, p<0.001), suggesting the IQR-to-median ratio of CAP would be an inappropriate validity parameter. In the derivation cohort, the IQR of CAP was associated with the accuracy of CAP (AUROC 0.86, 0.89 and 0.76 in patients with IQR of CAP <20 [15% of patients], 20-39 [51%], and ≥40dB/m [33%], respectively). Likewise, the AUROC of CAP in the validation cohort was 0.90 and 0.77 in patients with IQR of CAP <40 and ≥40dB/m, respectively (p=0.004). The accuracy of CAP in detecting grade 2 and 3 steatosis was lower among patients with body mass index ≥30kg/m2 and F3-4 fibrosis.

CONCLUSIONS

The validity of CAP for the diagnosis of fatty liver is lower if the IQR of CAP is ≥40dB/m. Lay summary: Controlled attenuation parameter (CAP) is measured by transient elastography (TE) for the detection of fatty liver. In this large study, using liver biopsy as a reference, we show that the variability of CAP measurements based on its interquartile range can reflect the accuracy of fatty liver diagnosis. In contrast, other clinical factors such as adiposity and liver enzyme levels do not affect the performance of CAP.

Для цитирования: Wong Vincent Wai-Sun, Petta Salvatore, Hiriart Jean-Baptiste, Cammà Calogero, Wong Grace Lai-Hung, Marra Fabio, Vergniol Julien, Chan Anthony Wing-Hung, Tuttolomondo Antonino, Merrouche Wassil, Chan Henry Lik-Yuen, Le Bail Brigitte, Arena Umberto, Craxì Antonio, de Lédinghen Victor. Validity criteria for the diagnosis of fatty liver by M probe-based controlled attenuation parameter.. Journal of hepatology. 2017. DOI: 10.1016/j.jhep.2017.05.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.