DOI 10.1007/s11547-016-0708-4

Медицинская библиотека · La Radiologia medica · 2016

Inappropriateness of diagnostic imaging examinations in the inpatient setting: a case study research.

Squillaci Ettore, Bolacchi Francesca, Scaggiante Jacopo, Ricci Francesca, Pugliese Luca, Bergamini Alberto, Garaci Francesco, Floris Roberto

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of our study was to audit the clinical appropriateness of the prescriptions of whole body CT (WB-CT), PET-CT and chest X-rays (CXRs) performed at Tor Vergata University Hospital in the inpatient setting.

MATERIALS AND

METHODS

WB-CT, PET-CT and CXRs examinations were retrospectively analysed in the period between January and December 2014. CXR examinations were divided into bedside CXRs and traditional CXRs. The appropriateness of the examinations was defined according the American College of Radiology Appropriateness Criteria. Inappropriate examinations were divided into six inappropriateness categories in accordance with the European Union Medical Imaging Guidelines.

RESULTS

Appropriateness was suboptimal for all analysed techniques CXRs (A = 38%, I = 62%); bedside CXRs (A = 45%, I = 53%); WB-CT (A = 45%, I = 55%); PET-CT (A = 48%, I = 52%). With respect to WB-CT the highest rate of inappropriate imaging prescriptions came from the haematology clinical operative unit (OU) (44%) and emergency medicine (33%); with respect to PET-CT, the thoracic surgery OU (53%) and haematology OU (48%) showed the most inappropriate prescriptions. For CXRs, the percentage of inappropriateness was consistently distributed among all surgical OUs. For bedside CXRs, the largest inappropriate prescribers were the emergency medicine OU (48%), the cardiac surgery OU (58%), the intensive care OU (67%) and anaesthesia resuscitation OU (78%). The most represented classes of inappropriateness were 2, 3, 4 and 6.

CONCLUSIONS

The elimination of inappropriate prescriptions would result in an annual savings of approximately 390,000 Euro. An implementation plan to increase prescription appropriateness is under development by our group.

Для цитирования: Squillaci Ettore, Bolacchi Francesca, Scaggiante Jacopo, Ricci Francesca, Pugliese Luca, Bergamini Alberto, Garaci Francesco, Floris Roberto. Inappropriateness of diagnostic imaging examinations in the inpatient setting: a case study research.. La Radiologia medica. 2016. DOI: 10.1007/s11547-016-0708-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.