MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/neurintsurg-2015-011836.rep

Медицинская библиотека · Journal of neurointerventional surgery · 2015

Treatment of wide-necked basilar tip aneurysm not amenable to Y-stenting using the PulseRider device.

Sheth Sunil A, Patel Nirav S, Ismail Ameera F, Freeman Dena, Duckwiler Gary, Tateshima Satoshi

СтатьяПеревод пока не подготовлен

Аннотация

Endovascular treatment of broad-necked bifurcation aneurysms remains challenging. Stent-assisted coiling has been successful but requires catheterization of the branches off the parent vessel. We present the case of a patient who failed primary and stent-assisted coiling of a large basilar tip aneurysm because the morphology of the aneurysm precluded successful distal catheterization of the posterior cerebral artery (PCA) branches. Using the PulseRider device, which does not require catheterization of bifurcation branches, we were able to treat the aneurysm successfully.

Для цитирования: Sheth Sunil A, Patel Nirav S, Ismail Ameera F, Freeman Dena, Duckwiler Gary, Tateshima Satoshi. Treatment of wide-necked basilar tip aneurysm not amenable to Y-stenting using the PulseRider device.. Journal of neurointerventional surgery. 2015. DOI: 10.1136/neurintsurg-2015-011836.rep.