MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001465

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2022

Optimal Hemodynamics and Risk of Severe Outcomes Post-Left Ventricular Assist Device Implantation.

Rosenbaum Andrew N, Ternus Bradley W, Stulak John M, Clavell Alfredo L, Schettle Sarah D, Behfar Atta, Jentzer Jacob C

СтатьяПеревод пока не подготовлен

Аннотация

Data on pre-implant hemodynamic optimization before continuous flow left ventricular assist device placement (CF-LVAD) with respect to patient-centered outcomes remain limited. Consecutive patients undergoing CF-LVAD implant between 2007 and 2017 were identified. Hemodynamic variables, trends, and laboratory studies were evaluated pre-LVAD implant in a logistic regression model to identify predictors of the primary composite endpoint: the need for right ventricular assist device therapy, the requirement for hemodialysis at 90 days, and 30-day mortality. Multivariate modeling identified three variables significantly associated with the primary endpoint: right ventricular stroke work index (RVSWI), right atrial pressure (RAP), and blood urea nitrogen (BUN); all immediately pre-LVAD, p < 0.01. Optimal dichotomization points were 500 mmHg*ml*m-2, 12 mmHg, and 40 mg/dL. The three-component model identified an AUC of 0.77 (p < 0.0001) for the composite endpoint. Optimization of 2/3 parameters, 1/3, and 0/3 was associated with odds ratios of 3.5 (95% CI, 1.1-11.7), 7.2 (95% CI, 2.1-24.2), and 20.6 (95% CI, 5.3-80.6), respectively, relative to those patients who were fully optimized (3/3 parameters). The number of optimized parameters was also associated with 1-year overall survival (p = 0.02). Low RVSWI, high RAP, and high BUN were independently associated with adverse outcomes after the CF-LVAD implant, demonstrating a stepwise association with severe postimplant adverse events.

Для цитирования: Rosenbaum Andrew N, Ternus Bradley W, Stulak John M, Clavell Alfredo L, Schettle Sarah D, Behfar Atta, Jentzer Jacob C. Optimal Hemodynamics and Risk of Severe Outcomes Post-Left Ventricular Assist Device Implantation.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2022. DOI: 10.1097/mat.0000000000001465.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.