The American journal of cardiology · 2022
Meta-Analysis Comparing Risk Factors, Incidence, and Outcomes of Patients With Versus Without Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Implantation.
СтатьяМетаанализНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lim Oliver Zi Hern, Mai Aaron Shengting, Ng Chen Han, Tang Ansel, Chin Yip Han, Kong Gwyneth, Ho Yeung Jek, Ong Joy, Tay Edgar, Kuntjoro Ivandito, Chew Nicholas Ws, Lim Yinghao
Аннотация
Current guidelines on the management of patients with aortic valvular disease have widened the use of transcatheter aortic valve implantation (TAVI) with an emphasis on avoidance of prosthesis-patient mismatch (PPM). This study sought to examine the incidence, risk factors, and all-cause mortality of PPM after TAVI. Medline and Embase databases were searched from inception to August 10, 2021. Patients were compared along 2 arms: (1) any degree of PPM and those without PPM, (2) severe PPM, and nonsevere PPM. A total of 22 articles involving 115,442 patients after TAVI were included. Pooled incidence for any degree of PPM was 30.1% and 10.7% in severe PPM. Incidence was significantly higher (p <0.001) for any degree of PPM in Europe (33.1%) and North America (34.4%) compared with Asia (10.4%). Incidence of severe PPM was higher (p = 0.015) in older generation (13.6%) compared with current-generation valves (6.3%). Severe PPM increased the risk of all-cause mortality relative to nonsevere PPM (hazard ratio: 1.86, 95% confidence interval: 1.05 to 3.29, p = 0.034). Patients of younger age, increased body surface area, lower left ventricular ejection fraction, and classified New York Heart Association Class III/IV were at greater risk of both any degree and severe PPM. Smaller prosthesis size increased the risk of any degree of PPM, whereas postdilation and larger prostheses were protective factors. In conclusion, all-cause mortality was significantly affected in severe PPM compared with nonsevere cases, whereas this excess mortality was not observed between those with any degree of PPM and those without. Closer attention to patient and bioprosthetic valve factors is required to minimize the occurrence of severe PPM.