Аннотация

The incidence of acute coronary obstruction during transcatheter aortic valve implantation (TAVI) is low (< 1.0%); however, it is associated with high mortality. An 83-year-old female with a history of chest pain and syncope was diagnosed with severe aortic stenosis. Computed tomography showed severely calcified aortic leaflets with a low left coronary ostial height of 7.8 mm, which indicates a high risk of coronary obstruction. TAVI was performed using the right femoral artery approach under general anesthesia. To prevent coronary obstruction and minimize coronary flow obstruction, coronary protection of the left main tract (LMT) via the left radial artery was established with a perfusion balloon. We crossed a 23 mm Sapien 3 transcatheter heart valve and settled it at an appropriate position on the aortic valve. After inflation of the perfusion balloon at the LMT, we started rapid ventricular pacing, and deployed the Sapien 3 using the KBI technique. Hemodynamics were stable and aortography showed excellent coronary flow with no stenosis of the LMT ostium. This strategy may serve as a useful method to prevent coronary obstruction and minimize coronary ischemia.

Для цитирования: Hashimoto Naoto, Tamura Harutoshi, Otaki Yoichiro, Takahata Aoi, Tsuchiya Hayato, Sugai Takayuki, Yamashita Atsushi, Wanezaki Masahiro, Nishiyama Satoshi, Watanabe Tetsu, Uchida Tetsuro, Watanabe Masafumi. Perfusion Balloon Is Useful for Preventing Obstruction of Left Main Coronary Artery During Transcatheter Aortic Valve Implantation.. International heart journal. 2022. DOI: 10.1536/ihj.21-275.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.