MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.semtcvs.2021.08.028

Медицинская библиотека · Seminars in thoracic and cardiovascular surgery · 2021

Longitudinal Hemodynamics of Aortic Bioprosthetic Valve in Hemodialysis Patients.

Kinoshita Takeshi, Yoshida Kumi, Suzuki Tomoaki, Asai Tohru

СтатьяПеревод пока не подготовлен

Аннотация

We examined the hemodynamic profile of bioprosthetic aortic valves in patients on hemodialysis (HD), longitudinally, and assess the incidence of adverse changes detected by echocardiography. Of 1,146 consecutive patients with severe aortic stenosis who underwent bioprosthetic aortic valve replacement (AVR), 148 patients had end-stage renal disease requiring HD. Each patient on HD was matched one-to-one with a non-HD patient on the basis of propensity scores. The mean follow-up period was 3.3 years for the HD group and 5.9 years for the non-HD group. Follow-up information was available for 95.2%. Postoperative trends of valve hemodynamics derived from linear mixed-effect models showed significant group vs time interactions between the two groups. Stable hemodynamics was consistently observed in the non-HD group, whereas the HD group showed a decrease of -0.06 cm2/y (95% confidence interval (CI), -0.10 to -0.02) in effective orifice area, an increase of 0.8 mm Hg/year (95% CI, 0.4-1.1) in mean pressure gradient, and an increase of 0.08 m/s/year (95%CI, 0.02-0.13) in peak velocity. Cumulative incidence function of SVD more than stage 2 was significantly higher in the HD group (13.1% vs 3.1% at 5 years, Gray test p = 0.01). In a multivariable Fine-Gray analysis, diabetes was independently associated with SVD more than stage 2 in the HD group (subhazard ratio, 1.91; 95% CI, 1.25-2.89; p = 0.02). Survival free-from stenotic-type SVD was significantly lower in HD patients undergoing bioprosthetic AVR. Diabetes was independently associated with postoperative stenotic-type SVD in HD patients.

Для цитирования: Kinoshita Takeshi, Yoshida Kumi, Suzuki Tomoaki, Asai Tohru. Longitudinal Hemodynamics of Aortic Bioprosthetic Valve in Hemodialysis Patients.. Seminars in thoracic and cardiovascular surgery. 2021. DOI: 10.1053/j.semtcvs.2021.08.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.