MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000517279

Медицинская библиотека · Blood purification · 2021

Factors Associated with Coronary In-Stent Restenosis after Drug-Eluting Stent Implantation in Patients on Chronic Hemodialysis.

Sugita Hiroshi, Motohiro Masayuki, Morishita Syun, Tanaka Masami, Tsujimoto Satoshi, Shiojima Ichiro

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Recently, drug-eluting stents (DESs) have been widely adopted for patients on chronic hemodialysis (HD). However, whether DES implantation is associated with a reduced rate of in-stent restenosis (ISR) is unclear. We investigated the incidence of ISR and its predictors in patients on HD after DES implantation.

METHODS AND

RESULTS

We analyzed 194 consecutive patients (331 lesions) on HD who underwent follow-up angiography after DES implantation. ISR was observed in 74 lesions (22.4%). Angiographically, the relative incidence of AHA/ACC type C lesion was increased (47 vs. 32%; p = 0.043), the minimal lumen diameter (MLD) before DES implantation was smaller (0.82 ± 0.49 vs. 0.97 ± 0.45 mm; p < 0.01), and the lesion length (LL) was increased (30.2 ± 16.1 vs. 24.4 ± 12.1 mm; p = 0.023) in lesions with ISR compared to those without ISR. The rate of rotational atherectomy use was also increased in lesions with ISR compared to those without ISR (50% vs. 25%; p < 0.01). In a multivariate analysis, the MLD before DES implantation (odds ratio [OR] = 0.50, 95% confidence interval [CI] 0.27-0.91, p = 0.024), LL (OR = 1.02, 95% CI 1.00-1.04, p = 0.030) and the use of rotational atherectomy (OR = 2.71, 95% CI 1.55-4.72, p < 0.01) were independent predictors of ISR. The incidence of ISR was similar between lesions treated with the first-generation (25.8%) and the second-generation DESs (20.4%).

CONCLUSIONS

ISR was observed in 74 lesions (22.4%). A small MLD, long LL, and the use of rotational atherectomy were independent predictors of ISR after DES implantation in patients on HD. There was no significant difference in the ISR rate between the first- and the second-generation DESs.

Для цитирования: Sugita Hiroshi, Motohiro Masayuki, Morishita Syun, Tanaka Masami, Tsujimoto Satoshi, Shiojima Ichiro. Factors Associated with Coronary In-Stent Restenosis after Drug-Eluting Stent Implantation in Patients on Chronic Hemodialysis.. Blood purification. 2021. DOI: 10.1159/000517279.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.