Stroke Severity in Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Synnott Pádraig, Murphy Robert P, Judge Conor, Costello Maria, Reddin Catriona, Dennehy Karen, Loughlin Elaine, Smyth Andrew, Mylotte Darren, O'Donnell Martin J, Canavan Michelle

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVES

An assessment of the comparative incidence of fatal or disabling stroke may influence choice of intervention for patients with severe aortic stenosis. We explored whether transcatheter aortic valve implantation (TAVI) is associated with a lower incidence of fatal or disabling stroke, compared to surgical aortic valve replacement (SAVR).

MATERIALS &

METHODS

We classified stroke into two categories; fatal or disabling, or non-disabling, and completed meta-analyses for each. We explored randomised controlled trials to assess the effect publication year, predicted operative risk, and route of TAVI access.

RESULTS

There was no difference between treatment groups per 100 person years of follow up for disabling or non-disabling stroke outcomes. In a stratified analysis by year of publication, there was a lower rate of fatal or disabling stroke with TAVI in trials published after 2015, compared to those published in 2015 or before (p-interaction = 0.01 at 30 days). Higher proportions of transfemoral route access (>90%), more common in recent trials, were associated with a lower rate of fatal or disabling stroke (p-interaction = 0.03 at 30 days). Lower average surgical risk scores were associated with lower rates of fatal or disabling stroke (p = 0.02 at 30 days).

CONCLUSION

We found that treatment of aortic stenosis with TAVI compared with SAVR was not associated with an overall reduced risk in fatal or disabling stroke. Subgroup analyses suggested a lower risk of fatal or disabling stroke with TAVI in situations which reflect contemporary practice.

Для цитирования: Synnott Pádraig, Murphy Robert P, Judge Conor, Costello Maria, Reddin Catriona, Dennehy Karen, Loughlin Elaine, Smyth Andrew, Mylotte Darren, O'Donnell Martin J, Canavan Michelle. Stroke Severity in Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement: A Systematic Review and Meta-Analysis.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2021. DOI: 10.1016/j.jstrokecerebrovasdis.2021.105927.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.