MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diabres.2023.110735

Медицинская библиотека · Diabetes research and clinical practice · 2023

Real-life 24-week changes in glycemic parameters among European users of flash glucose monitoring with type 1 and 2 diabetes and different levels of glycemic control.

Lameijer Annel, Bakker Julia J, Kao Kalvin, Xu Yongjin, Gans Rijk O B, Bilo Henk J G, Dunn Timothy C, van Dijk Peter R

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate real-life changes of glycemic parameters among flash glucose monitoring (FLASH) users who do not meet glycemic targets.

METHODS

De-identified data were obtained between 2014 and 2021 from patients using FLASH uninterrupted for a 24-week period. Glycemic parameters during first and last sensor use were examined in four identifiable groups: type 1 diabetes mellitus (T1DM), type 2 diabetes mellitus (T2DM) on basal-bolus insulin, T2DM on basal insulin, and T2DM without insulin treatment. Within each group, subgroup analyses were performed in persons with initial suboptimal glycemic regulation (time in range (TIR; 3.9-10 mmol/L) < 70%, time above range (TAR; >10 mmol/L) > 25%, or time below range (TBR; <3.9 mmol/L) > 4%).

RESULTS

Data were obtained from 1,909 persons with T1DM and 1,813 persons with T2DM (1,499 basal-bolus insulin, 189 basal insulin, and 125 non-insulin users). In most of the performed analyses, both overall and in the various subgroups, significant improvements were observed in virtually all predefined primary (TIR) and secondary endpoints (eHbA1c, TAR, TBR and glucose variability).

CONCLUSIONS

24-weeks FLASH use in real life by persons with T1DM and T2DM with suboptimal glycemic regulation is associated with improvement of glycemic parameters, irrespective of pre-use regulation or treatment modality.

Для цитирования: Lameijer Annel, Bakker Julia J, Kao Kalvin, Xu Yongjin, Gans Rijk O B, Bilo Henk J G, Dunn Timothy C, van Dijk Peter R. Real-life 24-week changes in glycemic parameters among European users of flash glucose monitoring with type 1 and 2 diabetes and different levels of glycemic control.. Diabetes research and clinical practice. 2023. DOI: 10.1016/j.diabres.2023.110735.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.