MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rct.0b013e3182a90ee7

Медицинская библиотека · Journal of computer assisted tomography · 2014

Midtreatment evaluation of lymphoma response to chemotherapy by volume perfusion computed tomography.

Spira Daniel, Grünwald Leonard, Vogel Wichard, Sauter Alexander, Spira Sven Michael, Claussen Claus Detlef, Horger Marius

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to search for chemotherapy-induced perfusion changes of diffuse large B-cell lymphoma, follicular lymphoma, and Hodgkin lymphoma at midtreatment versus baseline volume perfusion computed tomography (VPCT).

METHODS

Forty-five consecutive patients with untreated diffuse large B-cell lymphoma, follicular lymphoma, and Hodgkin lymphoma received VPCT examinations of the tumor bulk at baseline and during chemotherapy (midtreatment). Blood flow (BF), blood volume (BV), and transit constant (K-trans) were determined. Treatment response was categorized according to the Cheson criteria into complete or partial remission and stable or relapsed/progressive disease.

RESULTS

Midtreatment follow-up showed a reduction in BF, BV, and K-trans in all lymphoma subtypes compared with baseline. The reduction in BV was less pronounced in larger tumors. Notably, BF, BV, and K-trans decreased in the responders (complete remission/partial remission) when compared with the nonresponders (stable or relapsed/progressive disease). Less than 10% reduction in BF was shown to be the best VPCT criterion for the identification of nonresponse.

CONCLUSIONS

Chemotherapy-induced perfusion changes in responders are recognizable at midtreatment VPCT.

Для цитирования: Spira Daniel, Grünwald Leonard, Vogel Wichard, Sauter Alexander, Spira Sven Michael, Claussen Claus Detlef, Horger Marius. Midtreatment evaluation of lymphoma response to chemotherapy by volume perfusion computed tomography.. Journal of computer assisted tomography. 2014. DOI: 10.1097/rct.0b013e3182a90ee7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.