MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diii.2013.07.008

Медицинская библиотека · Diagnostic and interventional imaging · 2013

PET-CT and diagnostic CT: the synergy of metabolic and morphological data in onco-haematology.

Ricard F, Giammarile F, Tychyj-Pinel C, Houzard C, Decullier E, Chateau F, Manichon A F, Orliaguet I, Michallet A S, Salles G, Valette P J, Réty F

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Our goal was to determine how interpreting diagnostic CT together with PET-CT could improve the assessment of morphology in onco-haematology.

PATIENTS AND

METHODS

Fifty-nine patients with aggressive lymphoma were retrospectively included. The diagnostic CT scan was interpreted by two radiologists, followed by a combined analysis of the CT and the PET-CT carried out by two specialists in metabolic and morphological imaging. The diagnostic performances were assessed in terms of sensitivity and specificity, then concordance and discordance rates (kappa) were studied.

RESULTS

A combined interpretation of CT and PET-CT showed better diagnostic performances than those of interpretations of CT only in the assessment of nodal sites (826 sites, sensitivity of 99% versus 85%, P<0.05), extranodal sites (649 sites, sensitivity of 88% versus 78%) and bone sites (one analysed per patient, sensitivity of 50% versus 27%). The combined interpretation also improved inter-observer agreement and led to an upgraded Ann Arbor staging in 15% of patients, with a change of treatment in 10%.

CONCLUSION

Interpretation of diagnostic CT in onco-haematology can be improved by combining it with an assessment of PET-CT. The synergy between metabolic and morphological information leads to improved diagnostic capabilities and renders interpretations more reproducible.

Для цитирования: Ricard F, Giammarile F, Tychyj-Pinel C, Houzard C, Decullier E, Chateau F, Manichon A F, Orliaguet I, Michallet A S, Salles G, Valette P J, Réty F. PET-CT and diagnostic CT: the synergy of metabolic and morphological data in onco-haematology.. Diagnostic and interventional imaging. 2013. DOI: 10.1016/j.diii.2013.07.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.